Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit a5f8ae21 authored by Axel Lin's avatar Axel Lin Committed by Mark Brown
Browse files

regulator: palmas: Fix calculating selector in palmas_map_voltage_ldo



This patch fixes below issues when choosing selector:

1. Current code returns negative selector if min_uV < 900000 which is wrong.
   For example, it is possible to satisfy the request with selector = 1 if
   the requested min_uV is 850000.
2. Current code may select a voltage lower than requested min_uV.
   For example, if the requested min_uV is 945000, current code chooses
   selector = 1 which is lower than requested min_uV.
   DIV_ROUND_UP to avoid this case.

Signed-off-by: default avatarAxel Lin <axel.lin@gmail.com>
Signed-off-by: default avatarMark Brown <broonie@opensource.wolfsonmicro.com>
parent 0d7614f0
Loading
Loading
Loading
Loading
+6 −3
Original line number Diff line number Diff line
@@ -486,9 +486,12 @@ static int palmas_map_voltage_ldo(struct regulator_dev *rdev,
{
	int ret, voltage;

	ret = ((min_uV - 900000) / 50000) + 1;
	if (ret < 0)
		return ret;
	if (min_uV == 0)
		return 0;

	if (min_uV < 900000)
		min_uV = 900000;
	ret = DIV_ROUND_UP(min_uV - 900000, 50000) + 1;

	/* Map back into a voltage to verify we're still in bounds */
	voltage = palmas_list_voltage_ldo(rdev, ret);