Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit a00afb97 authored by Jean Delvare's avatar Jean Delvare
Browse files

hwmon: (it87) Don't arbitrarily enable temperature channels



Temperature channels can be used in 2 different modes (thermistor and
thermal diode) and we don't know which one, if any, is correct for
every given board. So don't arbitrarily choose one. Instead, leave the
temperature channels untouched. They can be configured from user-space
if needed anyway.

Signed-off-by: default avatarJean Delvare <khali@linux-fr.org>
parent c7a78d2c
Loading
Loading
Loading
Loading
+5 −8
Original line number Diff line number Diff line
@@ -545,6 +545,7 @@ static ssize_t set_sensor(struct device *dev, struct device_attribute *attr,

	mutex_lock(&data->update_lock);

	data->sensor = it87_read_value(data, IT87_REG_TEMP_ENABLE);
	data->sensor &= ~(1 << nr);
	data->sensor &= ~(8 << nr);
	if (val == 2) {	/* backwards compatibility */
@@ -1841,14 +1842,10 @@ static void __devinit it87_init_device(struct platform_device *pdev)
			it87_write_value(data, IT87_REG_TEMP_HIGH(i), 127);
	}

	/* Check if temperature channels are reset manually or by some reason */
	tmp = it87_read_value(data, IT87_REG_TEMP_ENABLE);
	if ((tmp & 0x3f) == 0) {
		/* Temp1,Temp3=thermistor; Temp2=thermal diode */
		tmp = (tmp & 0xc0) | 0x2a;
		it87_write_value(data, IT87_REG_TEMP_ENABLE, tmp);
	}
	data->sensor = tmp;
	/* Temperature channels are not forcibly enabled, as they can be
	 * set to two different sensor types and we can't guess which one
	 * is correct for a given system. These channels can be enabled at
	 * run-time through the temp{1-3}_type sysfs accessors if needed. */

	/* Check if voltage monitors are reset manually or by some reason */
	tmp = it87_read_value(data, IT87_REG_VIN_ENABLE);