Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 3e2b9abd authored by Mark Brown's avatar Mark Brown Committed by Liam Girdwood
Browse files

regulator: Don't warn on omitted voltage constraints



Specifying voltage constraints is optional (and only needed if the
consumer is allowed to change the voltage) so don't complain unless
a voltage has been specified.

Also avoid surprises with a dangling else while we're here.

Signed-off-by: default avatarMark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: default avatarLiam Girdwood <lrg@slimlogic.co.uk>
parent 216765d9
Loading
Loading
Loading
Loading
+5 −1
Original line number Diff line number Diff line
@@ -709,8 +709,12 @@ static int set_machine_constraints(struct regulator_dev *rdev,
			cmax = INT_MAX;
		}

		/* voltage constraints are optional */
		if ((cmin == 0) && (cmax == 0))
			goto out;

		/* else require explicit machine-level constraints */
		else if (cmin <= 0 || cmax <= 0 || cmax < cmin) {
		if (cmin <= 0 || cmax <= 0 || cmax < cmin) {
			pr_err("%s: %s '%s' voltage constraints\n",
				       __func__, "invalid", name);
			ret = -EINVAL;