net: pxa168_eth: fix Ethernet flow control status



IEEE 802.3x Ethernet flow control is disabled when bit (1 << 2) is set
in the port status register. Fix the flow control detection in the link
event handling function which was relying on the opposite assumption.

Signed-off-by: default avatarAntoine Tenart <antoine.tenart@free-electrons.com>
Acked-by: default avatarArnd Bergmann <arnd@arndb.de>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 18b4bad3
Loading
Loading
Loading
Loading
+2 −2
Original line number Diff line number Diff line
@@ -163,7 +163,7 @@
/* Bit definitions for Port status */
#define PORT_SPEED_100		(1 << 0)
#define FULL_DUPLEX		(1 << 1)
#define FLOW_CONTROL_ENABLED	(1 << 2)
#define FLOW_CONTROL_DISABLED	(1 << 2)
#define LINK_UP			(1 << 3)

/* Bit definitions for work to be done */
@@ -885,7 +885,7 @@ static void handle_link_event(struct pxa168_eth_private *pep)
		speed = 10;

	duplex = (port_status & FULL_DUPLEX) ? 1 : 0;
	fc = (port_status & FLOW_CONTROL_ENABLED) ? 1 : 0;
	fc = (port_status & FLOW_CONTROL_DISABLED) ? 0 : 1;
	netdev_info(dev, "link up, %d Mb/s, %s duplex, flow control %sabled\n",
		    speed, duplex ? "full" : "half", fc ? "en" : "dis");
	if (!netif_carrier_ok(dev))