Commit f0fcd7a9 authored by Nithin Sujir's avatar Nithin Sujir Committed by David S. Miller
Browse files

tg3: Fix flow control settings not propagated to hardware



In tg3_setup_copper_phy(), if autonegotiation is disabled, we need to
relink only if the speed or duplex does not match the configured
setting.  If flow control does not match, a relink is not necessary as
flow control is not a PHY setting.  Later on, we'll call
tg3_setup_flow_ctrl() to set up the MAC to the desired flow control
settings if we're in full duplex mode.

Signed-off-by: default avatarNithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: default avatarMichael Chan <mchan@broadcom.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 1b866434
Loading
Loading
Loading
Loading
+1 −3
Original line number Diff line number Diff line
@@ -4587,9 +4587,7 @@ static int tg3_setup_copper_phy(struct tg3 *tp, int force_reset)
		} else {
			if (!(bmcr & BMCR_ANENABLE) &&
			    tp->link_config.speed == current_speed &&
			    tp->link_config.duplex == current_duplex &&
			    tp->link_config.flowctrl ==
			    tp->link_config.active_flowctrl) {
			    tp->link_config.duplex == current_duplex) {
				current_link_up = 1;
			}
		}