Commit 59970753 authored by Max Filippov's avatar Max Filippov Committed by Chris Zankel
Browse files

xtensa: call check_s32c1i after trap_init



Otherwise exceptions may occur prior to exception handling mechanism
initialization, resulting in silently dead system.

Signed-off-by: default avatarMax Filippov <jcmvbkbc@gmail.com>
Signed-off-by: default avatarChris Zankel <chris@zankel.net>
parent 62351531