dt-bindings: soc: Add clocks for Mediatek SCPSYS unit



Add clocks needed by Mediatek VENC and VENC_LT power domianis.
These clocks were needed by accessing subsystem's registers,
so they need to be enabled before power on these subsystems.

Signed-off-by: default avatarJames Liao <jamesjj.liao@mediatek.com>
Signed-off-by: default avatarMatthias Brugger <matthias.bgg@gmail.com>
parent 013f2a23
Loading
Loading
Loading
Loading
+6 −4
Original line number Diff line number Diff line
@@ -17,9 +17,9 @@ Required properties:
- reg: Address range of the SCPSYS unit
- infracfg: must contain a phandle to the infracfg controller
- clock, clock-names: clocks according to the common clock binding.
                      The clocks needed "mm" and "mfg". These are the
		      clocks which hardware needs to be enabled before
		      enabling certain power domains.
                      The clocks needed "mm", "mfg", "venc" and "venc_lt".
		      These are the clocks which hardware needs to be enabled
		      before enabling certain power domains.

Example:

@@ -30,7 +30,9 @@ Example:
		infracfg = <&infracfg>;
		clocks = <&clk26m>,
			 <&topckgen CLK_TOP_MM_SEL>;
		clock-names = "mfg", "mm";
			 <&topckgen CLK_TOP_VENC_SEL>,
			 <&topckgen CLK_TOP_VENC_LT_SEL>;
		clock-names = "mfg", "mm", "venc", "venc_lt";
	};

Example consumer: