Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 185d4c8b authored by Ariel Elior's avatar Ariel Elior Committed by David S. Miller
Browse files

bnx2x: remove false warning regarding interrupt number



Since version 7.4 the FW configures in the pci config space the max
number of interrupts available to the physical function, instead of
the exact number to use.
This causes a false warning in driver when comparing the number of
configured interrupts to the number about to be used.

Signed-off-by: default avatarAriel Elior <ariele@broadcom.com>
Signed-off-by: default avatarEilon Greenstein <eilong@broadcom.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent c0d680e5
Loading
Loading
Loading
Loading
+6 −5
Original line number Diff line number Diff line
@@ -9831,12 +9831,13 @@ static void __devinit bnx2x_get_igu_cam_info(struct bnx2x *bp)
	}

#ifdef CONFIG_PCI_MSI
	/*
	 * It's expected that number of CAM entries for this functions is equal
	 * to the number evaluated based on the MSI-X table size. We want a
	 * harsh warning if these values are different!
	/* Due to new PF resource allocation by MFW T7.4 and above, it's
	 * optional that number of CAM entries will not be equal to the value
	 * advertised in PCI.
	 * Driver should use the minimal value of both as the actual status
	 * block count
	 */
	WARN_ON(bp->igu_sb_cnt != igu_sb_cnt);
	bp->igu_sb_cnt = min_t(int, bp->igu_sb_cnt, igu_sb_cnt);
#endif

	if (igu_sb_cnt == 0)