Loading Documentation/devicetree/bindings/regulator/qpnp-labibb-regulator.txt +150 −51 Original line number Original line Diff line number Diff line Loading @@ -26,7 +26,7 @@ Main node optional properties: in LAB and IBB modules. Make sure the in LAB and IBB modules. Make sure the hardware has needed support before hardware has needed support before enabling this property. enabling this property. - qcom,swire-control: A bool property which indicates if the LAB/IBB is - qcom,swire-control: A boolean property which indicates if the LAB/IBB is controlled by the SWIRE interface. Enable only controlled by the SWIRE interface. Enable only if qcom,qpnp-labibb-mode = "amoled". if qcom,qpnp-labibb-mode = "amoled". - qcom,labibb-ttw-force-lab-on: A boolean property which forces LAB to be - qcom,labibb-ttw-force-lab-on: A boolean property which forces LAB to be Loading @@ -53,6 +53,15 @@ Main node optional properties: needed when LAB and IBB are operating needed when LAB and IBB are operating in standalone mode to vote for MBG. in standalone mode to vote for MBG. Following properties are available only for PM660A: - qcom,pbs-control: A boolean property which indicates if the LAB/IBB is controlled by the PBS sequencer. If this mode is enabled the PBS sequencer does the SWIRE remapping and program the voltages based on the SWIRE count. LAB subnode required properties: LAB subnode required properties: - reg: Specifies the SPMI address and size for this peripheral. - reg: Specifies the SPMI address and size for this peripheral. Loading @@ -72,29 +81,9 @@ LAB subnode required properties: is configured in amoled mode. is configured in amoled mode. - qcom,qpnp-lab-init-lcd-voltage: The default output voltage when LAB regulator - qcom,qpnp-lab-init-lcd-voltage: The default output voltage when LAB regulator is configured in lcd mode. is configured in lcd mode. - qcom,qpnp-lab-soft-start: The soft start time in us of LAB regulator. Supported value are 200, 400, 600 and 800. - qcom,qpnp-lab-ps-threshold: The threshold in mA of Pulse Skip Mode for - qcom,qpnp-lab-ps-threshold: The threshold in mA of Pulse Skip Mode for LAB regulator. Supported values are 20, 30, LAB regulator. Supported values are 20, 30, 40 and 50. 40 and 50. - qcom,qpnp-lab-pfet-size: PFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-nfet-size: NFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-max-precharge-time: Precharge time in uS for LAB regulator. Supported values are 200, 300, 400 and 500. Suggested values for LCD and AMOLED mode are 500 and 300uS respectively. - qcom,qpnp-lab-switching-clock-frequency: The PWM switching clock frequency in kHz of Lab regulator, Supported values are: 3200, 2740, 2400, 2130, 1920, 1750, 1600, 1480, 1370, 1280, 1200, 1130, 1070, 1010, 960, 910. - qcom,qpnp-lab-limit-maximum-current: The maximum inductor current limit in mA of LAB regulator. Supported values are 200, 400, 600, 800, 1000, 1200, 1400 and 1600. - interrupts: Specify the interrupts as per the interrupt - interrupts: Specify the interrupts as per the interrupt encoding. encoding. Currently "lab-vreg-ok" is required for Currently "lab-vreg-ok" is required for Loading Loading @@ -135,6 +124,23 @@ LAB subnode optional properties: enforce maximum inductor current constraint enforce maximum inductor current constraint for LAB regulator. Otherwise, there is no for LAB regulator. Otherwise, there is no maximum current constraint. maximum current constraint. - qcom,qpnp-lab-switching-clock-frequency: The PWM switching clock frequency in kHz of Lab regulator, Supported values are: 3200, 2740, 2400, 2130, 1920, 1750, 1600, 1480, 1370, 1280, 1200, 1130, 1070, 1010, 960, 910. - qcom,qpnp-lab-limit-maximum-current: The maximum inductor current limit in mA of LAB regulator. Supported values are 200, 400, 600, 800, 1000, 1200, 1400 and 1600. - qcom,qpnp-lab-pfet-size: PFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-nfet-size: NFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-max-precharge-time: Precharge time in uS for LAB regulator. Supported values are 200, 300, 400 and 500. Suggested values for LCD and AMOLED mode are 500 and 300uS respectively. - qcom,qpnp-lab-use-default-voltage: A boolean property which upon set will - qcom,qpnp-lab-use-default-voltage: A boolean property which upon set will use the value specified in use the value specified in qcom,qpnp-lab-init-voltage property. qcom,qpnp-lab-init-voltage property. Loading @@ -144,6 +150,40 @@ LAB subnode optional properties: output voltage can be configured to output voltage can be configured to any value in the allowed limit. any value in the allowed limit. Following properties are available only for PM660A: - qcom,qpnp-lab-soft-start: The soft start time in us of LAB regulator. Supported value are 200, 400, 600 and 800. - qcom,qpnp-lab-ldo-pulldown-enable: This property is used to enable/disable the LDO pull down. 1 - enable pulldown 0 - disable pulldown - qcom,qpnp-lab-enable-sw-high-psrr: A boolean property to enable the software high psrr (Power Suppy Rejection Rate) mode. - qcom,qpnp-lab-high-psrr-src-select: This property is used to select the LAB HW high psrr source. The supported values are: 0 = Either vph_high or high_psrr enable 1 = vph_high only 2 = high_psrr enable only 3 = Either vph_high or high_psrr enable This property is not valid if the qcom,qpnp-lab-enable-sw-high-psrr property is specified. - qcom,qpnp-lab-vref-high-psrr-select: This property is required if the qcom,qpnp-lab-high-psrr-src-select is specified. The supported values (in mV) are 350, 400, 450 and 500. Once the rejection rate crosses the selected high-psrr voltage the LDO is enabled based on the value specified under qcom,qpnp-lab-high-psrr-src-select property. This property is not valid if the qcom,qpnp-lab-enable-sw-high-psrr property is specified. IBB subnode required properties: IBB subnode required properties: - reg: Specifies the SPMI address and size for this peripheral. - reg: Specifies the SPMI address and size for this peripheral. Loading @@ -154,8 +194,6 @@ IBB subnode required properties: - qcom,qpnp-ibb-min-voltage: The minimum voltage in microvolts IBB regulator can support. - qcom,qpnp-ibb-min-voltage: The minimum voltage in microvolts IBB regulator can support. - qcom,qpnp-ibb-step-size: The step size in microvolts of IBB regulator. - qcom,qpnp-ibb-step-size: The step size in microvolts of IBB regulator. - qcom,qpnp-ibb-slew-rate: The time in us taken by the regulator to change voltage value in one step. - qcom,qpnp-ibb-soft-start: The soft start time in us of IBB regulator. - qcom,qpnp-ibb-soft-start: The soft start time in us of IBB regulator. - qcom,qpnp-ibb-init-voltage: The default initial voltage when the bootloader does - qcom,qpnp-ibb-init-voltage: The default initial voltage when the bootloader does Loading @@ -168,13 +206,41 @@ IBB subnode required properties: - qcom,qpnp-ibb-discharge-resistor: The discharge resistor in Kilo Ohms which - qcom,qpnp-ibb-discharge-resistor: The discharge resistor in Kilo Ohms which controls the soft start time. Supported values controls the soft start time. Supported values are 300, 64, 32 and 16. are 300, 64, 32 and 16. IBB subnode optional properties: - qcom,qpnp-ibb-slew-rate: The time (in us) taken by the regulator to change voltage value in one step. This property is not applicable to PM660A. The following properties can be used as an alternate. qcom,qpnp-ibb-slew-rate-config qcom,qpnp-ibb-fast-slew-rate qcom,qpnp-ibb-slow-slew-rate - qcom,qpnp-ibb-ps-enable: A boolean property which upon set will enable pulse skip mode for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-num-swire-trans: The number of SWIRE transactions after which the pulse skipping is enabled. This property is required when qpnp-ibb-smart-ps-enable property is set. - qcom,qpnp-ibb-neg-curr-limit: This property must be set when the qpnp-ibb-smart-ps-enable is specified. The supported values in mA are 1, 2, 3, 4, 5, 6 and 7. The recommended value is - qcom,qpnp-ibb-full-pull-down: A boolean property which upon set will enable the pull down strength of IBB regulator to full. Otherwise, the pull down strength is configured to half. - qcom,qpnp-ibb-pull-down-enable: A boolean property which upon set will enable the pull down for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-lab-pwrup-delay: Power up delay (in us) for IBB regulator when - qcom,qpnp-ibb-lab-pwrup-delay: Power up delay (in us) for IBB regulator when it is enabled or turned on. Supported values it is enabled or turned on. Supported values are 1000, 2000, 4000 and 8000. are 1000, 2000, 4000 and 8000. - qcom,qpnp-ibb-lab-pwrdn-delay: Power down delay (in us) for IBB regulator - qcom,qpnp-ibb-lab-pwrdn-delay: Power down delay (in us) for IBB regulator when it is disabled or turned off. Supported when it is disabled or turned off. Supported values are 1000, 2000, 4000 and 8000. values are 1000, 2000, 4000 and 8000. - qcom,qpnp-ibb-switching-clock-frequency: The PWM switching clock frequency in - qcom,qpnp-ibb-switching-clock-frequency: The PWM switching clock frequency in kHz of IBB regulator. Supported values kHz of IBB regulator. Supported values are: 3200, 2740, 2400, 2130, 1920, are: 3200, 2740, 2400, 2130, 1920, Loading @@ -189,19 +255,6 @@ IBB subnode required properties: 1400, 1450, 1500 and 1550. 1400, 1450, 1500 and 1550. - qcom,qpnp-ibb-debounce-cycle: The debounce cycle of IBB regulator. - qcom,qpnp-ibb-debounce-cycle: The debounce cycle of IBB regulator. Supported values are 8, 16, 32 and 64. Supported values are 8, 16, 32 and 64. IBB subnode optional properties: - qcom,qpnp-ibb-ps-enable: A boolean property which upon set will enable pulse skip mode for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-full-pull-down: A boolean property which upon set will enable the pull down strength of IBB regulator to full. Otherwise, the pull down strength is configured to half. - qcom,qpnp-ibb-pull-down-enable: A boolean property which upon set will enable the pull down for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-en-discharge: A boolean property which upon set will - qcom,qpnp-ibb-en-discharge: A boolean property which upon set will enable discharge for IBB regulator. enable discharge for IBB regulator. Otherwise, it is kept disabled. Otherwise, it is kept disabled. Loading @@ -220,12 +273,58 @@ IBB subnode optional properties: already. If it it not specified, then already. If it it not specified, then output voltage can be configured to output voltage can be configured to any value in the allowed limit. any value in the allowed limit. - qcom,output-voltage-one-pulse The expected voltage (in mV) of VDISN signal - qcom,output-voltage-one-pulse: The expected voltage (in mV) of VDISN signal on the first SWIRE pulse. This property on the first SWIRE pulse. This property can be specified only if 'qcom,swire-control' can be specified only if 'qcom,swire-control' is defined. The minimum and maximum values is defined. The minimum and maximum values are 1400mV and 7700mV. are 1400mV and 7700mV. Following properties are available only for PM660A: - qcom,qpnp-ibb-smart-ps-enable: A boolean property which upon set enables smart pulse skip mode for IBB regulator. Otherwise, it is disabled. This property is only applicable to PM660A. - qcom,qpnp-ibb-enable-pfm-mode: A boolean property which enables the IBB to work in pfm mode. - qcom,qpnp-ibb-pfm-peak-curr: The PFM peak current limit settings in mA. Supported values are 150, 200, 250, 300, 350, 400, 450 and 500. This property is required if the qcom,qpnp-ibb-enable-pfm-mode is true. - qcom,qpnp-ibb-pfm-hysteresis: The PFM hysteresis voltage threshold in mV. Supported values are 0, 25 and 50. This property is required if the qcom,qpnp-ibb-enable-pfm-mode is specified. - qcom,qpnp-ibb-overload-blank: A boolean property which upon set enables the IBB overload blanking. - qcom,qpnp-ibb-overload-debounce: The expected overload debounce time (in ms) values are 1, 2, 4 and 8. This property is required only when the qcom,qpnp-ibb-overload-blank is set. - qcom,qpnp-ibb-vreg-ok-debounce: The expected vreg-ok-debounce time (us) values are 4, 8, 16 and 32. This property is required only when the qcom,qpnp-ibb-overload-blank is set. - qcom,qpnp-ibb-slew-rate-config: A boolean property to configure the ibb fast/slow slew rate. Either qcom,qpnp-ibb-fast-slew-rate or qcom,qpnp-ibb-slow-slew-rate has to be specified. Otherwise the qcom,qpnp-ibb-slow-slew-rate takes precedence over the qcom,qpnp-ibb-fast-slew-rate. - qcom,qpnp-ibb-fast-slew-rate: This property is required if the qcom, qpnp-ibb-slew-rate-config property is specified. Supported values (in us) are 100, 200, 500, 1000, 2000, 10000, 12000 and 15000. - qcom,qpnp-ibb-slow-slew-rate: This property is required if the qcom, qpnp-ibb-slew-rate-config property is specified. Supported values (in us) are 100, 200, 500, 1000, 2000, 10000, 12000 and 15000. Example: Example: qcom,pmi8994@3 { qcom,pmi8994@3 { qpnp-labibb-regulator { qpnp-labibb-regulator { Loading Loading
Documentation/devicetree/bindings/regulator/qpnp-labibb-regulator.txt +150 −51 Original line number Original line Diff line number Diff line Loading @@ -26,7 +26,7 @@ Main node optional properties: in LAB and IBB modules. Make sure the in LAB and IBB modules. Make sure the hardware has needed support before hardware has needed support before enabling this property. enabling this property. - qcom,swire-control: A bool property which indicates if the LAB/IBB is - qcom,swire-control: A boolean property which indicates if the LAB/IBB is controlled by the SWIRE interface. Enable only controlled by the SWIRE interface. Enable only if qcom,qpnp-labibb-mode = "amoled". if qcom,qpnp-labibb-mode = "amoled". - qcom,labibb-ttw-force-lab-on: A boolean property which forces LAB to be - qcom,labibb-ttw-force-lab-on: A boolean property which forces LAB to be Loading @@ -53,6 +53,15 @@ Main node optional properties: needed when LAB and IBB are operating needed when LAB and IBB are operating in standalone mode to vote for MBG. in standalone mode to vote for MBG. Following properties are available only for PM660A: - qcom,pbs-control: A boolean property which indicates if the LAB/IBB is controlled by the PBS sequencer. If this mode is enabled the PBS sequencer does the SWIRE remapping and program the voltages based on the SWIRE count. LAB subnode required properties: LAB subnode required properties: - reg: Specifies the SPMI address and size for this peripheral. - reg: Specifies the SPMI address and size for this peripheral. Loading @@ -72,29 +81,9 @@ LAB subnode required properties: is configured in amoled mode. is configured in amoled mode. - qcom,qpnp-lab-init-lcd-voltage: The default output voltage when LAB regulator - qcom,qpnp-lab-init-lcd-voltage: The default output voltage when LAB regulator is configured in lcd mode. is configured in lcd mode. - qcom,qpnp-lab-soft-start: The soft start time in us of LAB regulator. Supported value are 200, 400, 600 and 800. - qcom,qpnp-lab-ps-threshold: The threshold in mA of Pulse Skip Mode for - qcom,qpnp-lab-ps-threshold: The threshold in mA of Pulse Skip Mode for LAB regulator. Supported values are 20, 30, LAB regulator. Supported values are 20, 30, 40 and 50. 40 and 50. - qcom,qpnp-lab-pfet-size: PFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-nfet-size: NFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-max-precharge-time: Precharge time in uS for LAB regulator. Supported values are 200, 300, 400 and 500. Suggested values for LCD and AMOLED mode are 500 and 300uS respectively. - qcom,qpnp-lab-switching-clock-frequency: The PWM switching clock frequency in kHz of Lab regulator, Supported values are: 3200, 2740, 2400, 2130, 1920, 1750, 1600, 1480, 1370, 1280, 1200, 1130, 1070, 1010, 960, 910. - qcom,qpnp-lab-limit-maximum-current: The maximum inductor current limit in mA of LAB regulator. Supported values are 200, 400, 600, 800, 1000, 1200, 1400 and 1600. - interrupts: Specify the interrupts as per the interrupt - interrupts: Specify the interrupts as per the interrupt encoding. encoding. Currently "lab-vreg-ok" is required for Currently "lab-vreg-ok" is required for Loading Loading @@ -135,6 +124,23 @@ LAB subnode optional properties: enforce maximum inductor current constraint enforce maximum inductor current constraint for LAB regulator. Otherwise, there is no for LAB regulator. Otherwise, there is no maximum current constraint. maximum current constraint. - qcom,qpnp-lab-switching-clock-frequency: The PWM switching clock frequency in kHz of Lab regulator, Supported values are: 3200, 2740, 2400, 2130, 1920, 1750, 1600, 1480, 1370, 1280, 1200, 1130, 1070, 1010, 960, 910. - qcom,qpnp-lab-limit-maximum-current: The maximum inductor current limit in mA of LAB regulator. Supported values are 200, 400, 600, 800, 1000, 1200, 1400 and 1600. - qcom,qpnp-lab-pfet-size: PFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-nfet-size: NFET size in percentage. Supported values are 25, 50, 75 and 100. - qcom,qpnp-lab-max-precharge-time: Precharge time in uS for LAB regulator. Supported values are 200, 300, 400 and 500. Suggested values for LCD and AMOLED mode are 500 and 300uS respectively. - qcom,qpnp-lab-use-default-voltage: A boolean property which upon set will - qcom,qpnp-lab-use-default-voltage: A boolean property which upon set will use the value specified in use the value specified in qcom,qpnp-lab-init-voltage property. qcom,qpnp-lab-init-voltage property. Loading @@ -144,6 +150,40 @@ LAB subnode optional properties: output voltage can be configured to output voltage can be configured to any value in the allowed limit. any value in the allowed limit. Following properties are available only for PM660A: - qcom,qpnp-lab-soft-start: The soft start time in us of LAB regulator. Supported value are 200, 400, 600 and 800. - qcom,qpnp-lab-ldo-pulldown-enable: This property is used to enable/disable the LDO pull down. 1 - enable pulldown 0 - disable pulldown - qcom,qpnp-lab-enable-sw-high-psrr: A boolean property to enable the software high psrr (Power Suppy Rejection Rate) mode. - qcom,qpnp-lab-high-psrr-src-select: This property is used to select the LAB HW high psrr source. The supported values are: 0 = Either vph_high or high_psrr enable 1 = vph_high only 2 = high_psrr enable only 3 = Either vph_high or high_psrr enable This property is not valid if the qcom,qpnp-lab-enable-sw-high-psrr property is specified. - qcom,qpnp-lab-vref-high-psrr-select: This property is required if the qcom,qpnp-lab-high-psrr-src-select is specified. The supported values (in mV) are 350, 400, 450 and 500. Once the rejection rate crosses the selected high-psrr voltage the LDO is enabled based on the value specified under qcom,qpnp-lab-high-psrr-src-select property. This property is not valid if the qcom,qpnp-lab-enable-sw-high-psrr property is specified. IBB subnode required properties: IBB subnode required properties: - reg: Specifies the SPMI address and size for this peripheral. - reg: Specifies the SPMI address and size for this peripheral. Loading @@ -154,8 +194,6 @@ IBB subnode required properties: - qcom,qpnp-ibb-min-voltage: The minimum voltage in microvolts IBB regulator can support. - qcom,qpnp-ibb-min-voltage: The minimum voltage in microvolts IBB regulator can support. - qcom,qpnp-ibb-step-size: The step size in microvolts of IBB regulator. - qcom,qpnp-ibb-step-size: The step size in microvolts of IBB regulator. - qcom,qpnp-ibb-slew-rate: The time in us taken by the regulator to change voltage value in one step. - qcom,qpnp-ibb-soft-start: The soft start time in us of IBB regulator. - qcom,qpnp-ibb-soft-start: The soft start time in us of IBB regulator. - qcom,qpnp-ibb-init-voltage: The default initial voltage when the bootloader does - qcom,qpnp-ibb-init-voltage: The default initial voltage when the bootloader does Loading @@ -168,13 +206,41 @@ IBB subnode required properties: - qcom,qpnp-ibb-discharge-resistor: The discharge resistor in Kilo Ohms which - qcom,qpnp-ibb-discharge-resistor: The discharge resistor in Kilo Ohms which controls the soft start time. Supported values controls the soft start time. Supported values are 300, 64, 32 and 16. are 300, 64, 32 and 16. IBB subnode optional properties: - qcom,qpnp-ibb-slew-rate: The time (in us) taken by the regulator to change voltage value in one step. This property is not applicable to PM660A. The following properties can be used as an alternate. qcom,qpnp-ibb-slew-rate-config qcom,qpnp-ibb-fast-slew-rate qcom,qpnp-ibb-slow-slew-rate - qcom,qpnp-ibb-ps-enable: A boolean property which upon set will enable pulse skip mode for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-num-swire-trans: The number of SWIRE transactions after which the pulse skipping is enabled. This property is required when qpnp-ibb-smart-ps-enable property is set. - qcom,qpnp-ibb-neg-curr-limit: This property must be set when the qpnp-ibb-smart-ps-enable is specified. The supported values in mA are 1, 2, 3, 4, 5, 6 and 7. The recommended value is - qcom,qpnp-ibb-full-pull-down: A boolean property which upon set will enable the pull down strength of IBB regulator to full. Otherwise, the pull down strength is configured to half. - qcom,qpnp-ibb-pull-down-enable: A boolean property which upon set will enable the pull down for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-lab-pwrup-delay: Power up delay (in us) for IBB regulator when - qcom,qpnp-ibb-lab-pwrup-delay: Power up delay (in us) for IBB regulator when it is enabled or turned on. Supported values it is enabled or turned on. Supported values are 1000, 2000, 4000 and 8000. are 1000, 2000, 4000 and 8000. - qcom,qpnp-ibb-lab-pwrdn-delay: Power down delay (in us) for IBB regulator - qcom,qpnp-ibb-lab-pwrdn-delay: Power down delay (in us) for IBB regulator when it is disabled or turned off. Supported when it is disabled or turned off. Supported values are 1000, 2000, 4000 and 8000. values are 1000, 2000, 4000 and 8000. - qcom,qpnp-ibb-switching-clock-frequency: The PWM switching clock frequency in - qcom,qpnp-ibb-switching-clock-frequency: The PWM switching clock frequency in kHz of IBB regulator. Supported values kHz of IBB regulator. Supported values are: 3200, 2740, 2400, 2130, 1920, are: 3200, 2740, 2400, 2130, 1920, Loading @@ -189,19 +255,6 @@ IBB subnode required properties: 1400, 1450, 1500 and 1550. 1400, 1450, 1500 and 1550. - qcom,qpnp-ibb-debounce-cycle: The debounce cycle of IBB regulator. - qcom,qpnp-ibb-debounce-cycle: The debounce cycle of IBB regulator. Supported values are 8, 16, 32 and 64. Supported values are 8, 16, 32 and 64. IBB subnode optional properties: - qcom,qpnp-ibb-ps-enable: A boolean property which upon set will enable pulse skip mode for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-full-pull-down: A boolean property which upon set will enable the pull down strength of IBB regulator to full. Otherwise, the pull down strength is configured to half. - qcom,qpnp-ibb-pull-down-enable: A boolean property which upon set will enable the pull down for IBB regulator. Otherwise, it is disabled. - qcom,qpnp-ibb-en-discharge: A boolean property which upon set will - qcom,qpnp-ibb-en-discharge: A boolean property which upon set will enable discharge for IBB regulator. enable discharge for IBB regulator. Otherwise, it is kept disabled. Otherwise, it is kept disabled. Loading @@ -220,12 +273,58 @@ IBB subnode optional properties: already. If it it not specified, then already. If it it not specified, then output voltage can be configured to output voltage can be configured to any value in the allowed limit. any value in the allowed limit. - qcom,output-voltage-one-pulse The expected voltage (in mV) of VDISN signal - qcom,output-voltage-one-pulse: The expected voltage (in mV) of VDISN signal on the first SWIRE pulse. This property on the first SWIRE pulse. This property can be specified only if 'qcom,swire-control' can be specified only if 'qcom,swire-control' is defined. The minimum and maximum values is defined. The minimum and maximum values are 1400mV and 7700mV. are 1400mV and 7700mV. Following properties are available only for PM660A: - qcom,qpnp-ibb-smart-ps-enable: A boolean property which upon set enables smart pulse skip mode for IBB regulator. Otherwise, it is disabled. This property is only applicable to PM660A. - qcom,qpnp-ibb-enable-pfm-mode: A boolean property which enables the IBB to work in pfm mode. - qcom,qpnp-ibb-pfm-peak-curr: The PFM peak current limit settings in mA. Supported values are 150, 200, 250, 300, 350, 400, 450 and 500. This property is required if the qcom,qpnp-ibb-enable-pfm-mode is true. - qcom,qpnp-ibb-pfm-hysteresis: The PFM hysteresis voltage threshold in mV. Supported values are 0, 25 and 50. This property is required if the qcom,qpnp-ibb-enable-pfm-mode is specified. - qcom,qpnp-ibb-overload-blank: A boolean property which upon set enables the IBB overload blanking. - qcom,qpnp-ibb-overload-debounce: The expected overload debounce time (in ms) values are 1, 2, 4 and 8. This property is required only when the qcom,qpnp-ibb-overload-blank is set. - qcom,qpnp-ibb-vreg-ok-debounce: The expected vreg-ok-debounce time (us) values are 4, 8, 16 and 32. This property is required only when the qcom,qpnp-ibb-overload-blank is set. - qcom,qpnp-ibb-slew-rate-config: A boolean property to configure the ibb fast/slow slew rate. Either qcom,qpnp-ibb-fast-slew-rate or qcom,qpnp-ibb-slow-slew-rate has to be specified. Otherwise the qcom,qpnp-ibb-slow-slew-rate takes precedence over the qcom,qpnp-ibb-fast-slew-rate. - qcom,qpnp-ibb-fast-slew-rate: This property is required if the qcom, qpnp-ibb-slew-rate-config property is specified. Supported values (in us) are 100, 200, 500, 1000, 2000, 10000, 12000 and 15000. - qcom,qpnp-ibb-slow-slew-rate: This property is required if the qcom, qpnp-ibb-slew-rate-config property is specified. Supported values (in us) are 100, 200, 500, 1000, 2000, 10000, 12000 and 15000. Example: Example: qcom,pmi8994@3 { qcom,pmi8994@3 { qpnp-labibb-regulator { qpnp-labibb-regulator { Loading