Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 87aa6300 authored by Gabriele A. Trombetti's avatar Gabriele A. Trombetti Committed by NeilBrown
Browse files

md/raid6: Fix raid-6 read-error correction in degraded state



Fix: Raid-6 was not trying to correct a read-error when in
singly-degraded state and was instead dropping one more device, going to
doubly-degraded state. This patch fixes this behaviour.

Tested-by: default avatarJanos Haar <janos.haar@netcenter.hu>
Signed-off-by: default avatarGabriele A. Trombetti <g.trombetti.lkrnl1213@logicschema.com>
Reported-by: default avatarJanos Haar <janos.haar@netcenter.hu>
Signed-off-by: default avatarNeilBrown <neilb@suse.de>
Cc: stable@kernel.org
parent 722154e4
Loading
Loading
Loading
Loading
+1 −1
Original line number Original line Diff line number Diff line
@@ -1527,7 +1527,7 @@ static void raid5_end_read_request(struct bio * bi, int error)


		clear_bit(R5_UPTODATE, &sh->dev[i].flags);
		clear_bit(R5_UPTODATE, &sh->dev[i].flags);
		atomic_inc(&rdev->read_errors);
		atomic_inc(&rdev->read_errors);
		if (conf->mddev->degraded)
		if (conf->mddev->degraded >= conf->max_degraded)
			printk_rl(KERN_WARNING
			printk_rl(KERN_WARNING
				  "raid5:%s: read error not correctable "
				  "raid5:%s: read error not correctable "
				  "(sector %llu on %s).\n",
				  "(sector %llu on %s).\n",