Commit 1ab9764b authored by David Collins's avatar David Collins
Browse files

ARM: dts: msm: use VDD_APC0/1 CPR open-loop voltage as ceiling for msm8994



Use the interpolated open-loop initial voltage values as per-
virtual-corner ceiling voltage values.  This ensures that the
closed-loop settled CPR voltages can never exceed the open-loop
voltages even when the device gets very hot.

Change-Id: I95042727944212353c23dbadcec9e92e7a1ccafc
Signed-off-by: default avatarDavid Collins <collinsd@codeaurora.org>
parent 31a41c69
Loading
Loading
Loading
Loading
+2 −0
Original line number Diff line number Diff line
@@ -648,6 +648,7 @@
					      790000 815000 835000 900000
					      935000 940000 965000 990000>;

		qcom,cpr-scaled-init-voltage-as-ceiling;
		qcom,cpr-voltage-scaling-factor-max = <0 0 2000 2000>;
		qcom,cpr-quot-adjust-scaling-factor-max = <0 2000 2000 2000>;
		qcom,cpr-corner-frequency-map =
@@ -735,6 +736,7 @@
					      935000 940000 960000 970000
					      990000>;

		qcom,cpr-scaled-init-voltage-as-ceiling;
		qcom,cpr-voltage-scaling-factor-max = <0 0 2000 2000>;
		qcom,cpr-quot-adjust-scaling-factor-max = <0 2000 2000 2000>;
		qcom,cpr-corner-frequency-map =