Commit bbb16fef authored by Srinivas Pandruvada's avatar Srinivas Pandruvada Committed by Rafael J. Wysocki
Browse files

ACPI / Fan: Use bus id as the name for non PNP0C0B (Fan) devices



The _ART (Active Cooling Relationship Table), specifies relationship
among heat generating sources to a target active cooling device like
fan. The _ART table refers to actual bus id name for specifying relationship.
Naming "Fan" is not enough as name in the _ART table can change on every
platform, to establish relationship for user space thermal controllers.

Signed-off-by: default avatarSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: default avatarRafael J. Wysocki <rafael.j.wysocki@intel.com>
parent b2776bf7
Loading
Loading
Loading
Loading
+7 −1
Original line number Diff line number Diff line
@@ -325,6 +325,7 @@ static int acpi_fan_probe(struct platform_device *pdev)
	struct thermal_cooling_device *cdev;
	struct acpi_fan *fan;
	struct acpi_device *device = ACPI_COMPANION(&pdev->dev);
	char *name;

	fan = devm_kzalloc(&pdev->dev, sizeof(*fan), GFP_KERNEL);
	if (!fan) {
@@ -346,7 +347,12 @@ static int acpi_fan_probe(struct platform_device *pdev)
		}
	}

	cdev = thermal_cooling_device_register("Fan", device,
	if (!strncmp(pdev->name, "PNP0C0B", strlen("PNP0C0B")))
		name = "Fan";
	else
		name = acpi_device_bid(device);

	cdev = thermal_cooling_device_register(name, device,
						&fan_cooling_ops);
	if (IS_ERR(cdev)) {
		result = PTR_ERR(cdev);