Commit ea5c64b0 authored by Benjamin Herrenschmidt's avatar Benjamin Herrenschmidt
Browse files

powerpc/windfarm: Improve display of fan speeds in sysfs



Controls registered as RPM and PWM fans are now displayed
with the "RPM" or "%" suffix respectively to make it
clearer to the user what the value actually means since
the fan type isn't otherwise obvious.

Signed-off-by: default avatarBenjamin Herrenschmidt <benh@kernel.crashing.org>
parent a94d72b1
Loading
Loading
Loading
Loading
+12 −1
Original line number Diff line number Diff line
@@ -164,13 +164,24 @@ static ssize_t wf_show_control(struct device *dev,
			       struct device_attribute *attr, char *buf)
{
	struct wf_control *ctrl = container_of(attr, struct wf_control, attr);
	const char *typestr;
	s32 val = 0;
	int err;

	err = ctrl->ops->get_value(ctrl, &val);
	if (err < 0)
		return err;
	return sprintf(buf, "%d\n", val);
	switch(ctrl->type) {
	case WF_CONTROL_RPM_FAN:
		typestr = " RPM";
		break;
	case WF_CONTROL_PWM_FAN:
		typestr = " %";
		break;
	default:
		typestr = "";
	}
	return sprintf(buf, "%d%s\n", val, typestr);
}

/* This is really only for debugging... */