Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit e9c0748b authored by Thomas Gleixner's avatar Thomas Gleixner
Browse files

itimer: Fix the itimer trace print format



Compiling powerpc64 results in:

include/trace/events/timer.h:279: warning:
format '%lu' expects type 'long unsigned int', but argument 4 has type 'cputime_t'
....

cputime_t on power is u64, which triggers the above warning.

Cast the cputime_t to unsigned long long and fix the print format
string. That works on both 32 and 64 bit architectures.

While at it change the print format for long variables from %lu to %ld.

Signed-off-by: default avatarThomas Gleixner <tglx@linutronix.de>
Cc: Xiao Guangrong <xiaoguangrong@cn.fujitsu.com>
parent 5f201907
Loading
Loading
Loading
Loading
+4 −4
Original line number Diff line number Diff line
@@ -301,8 +301,8 @@ TRACE_EVENT(itimer_state,
		__entry->interval_usec	= value->it_interval.tv_usec;
	),

	TP_printk("which=%d expires=%lu it_value=%lu.%lu it_interval=%lu.%lu",
		  __entry->which, __entry->expires,
	TP_printk("which=%d expires=%llu it_value=%ld.%ld it_interval=%ld.%ld",
		  __entry->which, (unsigned long long)__entry->expires,
		  __entry->value_sec, __entry->value_usec,
		  __entry->interval_sec, __entry->interval_usec)
);
@@ -331,8 +331,8 @@ TRACE_EVENT(itimer_expire,
		__entry->pid	= pid_nr(pid);
	),

	    TP_printk("which=%d pid=%d now=%lu", __entry->which,
		      (int) __entry->pid, __entry->now)
	TP_printk("which=%d pid=%d now=%llu", __entry->which,
		  (int) __entry->pid, (unsigned long long)__entry->now)
);

#endif /*  _TRACE_TIMER_H */