ARM: OMAP2+: voltage: ensure voltage used is exact voltage from OPP table



When using the SMPS regulators to scale voltages, the regulator
framework may pass a minimum voltage that is not an exact OPP voltage.
For the VC/VP controlled voltage domains, we must ensure that the
voltage requested is the exact voltage from the OPP table.  This is
especially critical when using SR.

To fix, voltdm_scale() uses the target voltage passed to walk through
the OPP voltages until it finds a voltage that is >= one of the OPP
voltages.

Cc: Tero Kristo <t-kristo@ti.com>
Cc: Nishanth Menon <nm@ti.com>
Signed-off-by: default avatarKevin Hilman <khilman@ti.com>
parent e160dda0
Loading
Loading
Loading
Loading
+18 −3
Original line number Diff line number Diff line
@@ -73,7 +73,8 @@ unsigned long voltdm_get_voltage(struct voltagedomain *voltdm)
int voltdm_scale(struct voltagedomain *voltdm,
		 unsigned long target_volt)
{
	int ret;
	int ret, i;
	unsigned long volt = 0;

	if (!voltdm || IS_ERR(voltdm)) {
		pr_warning("%s: VDD specified does not exist!\n", __func__);
@@ -86,9 +87,23 @@ int voltdm_scale(struct voltagedomain *voltdm,
		return -ENODATA;
	}

	ret = voltdm->scale(voltdm, target_volt);
	/* Adjust voltage to the exact voltage from the OPP table */
	for (i = 0; voltdm->volt_data[i].volt_nominal != 0; i++) {
		if (voltdm->volt_data[i].volt_nominal >= target_volt) {
			volt = voltdm->volt_data[i].volt_nominal;
			break;
		}
	}

	if (!volt) {
		pr_warning("%s: not scaling. OPP voltage for %lu, not found.\n",
			   __func__, target_volt);
		return -EINVAL;
	}

	ret = voltdm->scale(voltdm, volt);
	if (!ret)
		voltdm->nominal_volt = target_volt;
		voltdm->nominal_volt = volt;

	return ret;
}