iio: hid-sensor-magn-3d: Fix return values



IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored
the actual return values (which could be -EINVAL) and instead
returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value
obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO
upon success.

Signed-off-by: default avatarSachin Kamat <sachin.kamat@samsung.com>
Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
parent 2f084c17
Loading
Loading
Loading
Loading
+2 −5
Original line number Diff line number Diff line
@@ -110,7 +110,6 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
	struct magn_3d_state *magn_state = iio_priv(indio_dev);
	int report_id = -1;
	u32 address;
	int ret;
	int ret_type;
	s32 poll_value;

@@ -153,14 +152,12 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
		ret_type = IIO_VAL_INT;
		break;
	case IIO_CHAN_INFO_SAMP_FREQ:
		ret = hid_sensor_read_samp_freq_value(
		ret_type = hid_sensor_read_samp_freq_value(
			&magn_state->common_attributes, val, val2);
		ret_type = IIO_VAL_INT_PLUS_MICRO;
		break;
	case IIO_CHAN_INFO_HYSTERESIS:
		ret = hid_sensor_read_raw_hyst_value(
		ret_type = hid_sensor_read_raw_hyst_value(
			&magn_state->common_attributes, val, val2);
		ret_type = IIO_VAL_INT_PLUS_MICRO;
		break;
	default:
		ret_type = -EINVAL;