This issue happens only when we are associated with a 11n AP and power save is enabled. In the function 'ieee80211_master_start_xmit', ps_disable_work is queued where wake_queues is called. But before this work is executed, we check if the queues are stopped in _ieee80211_tx and return TX_AGAIN to ieee8011_tx which leads to the warning message. This patch fixes this erroneous case. Signed-off-by:Vivek Natarajan <vnatarajan@atheros.com> Signed-off-by:
John W. Linville <linville@tuxdriver.com>