Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 5f50245b authored by Eric W. Biederman's avatar Eric W. Biederman
Browse files

signal/alpha: Use send_sig_fault where appropriate



Filling in struct siginfo before calling send_sig_info a tedious and
error prone process, where once in a great while the wrong fields
are filled out, and siginfo has been inconsistently cleared.

Simplify this process by using the helper send_sig_fault.  Which
takes as a parameters all of the information it needs, ensures
all of the fiddly bits of filling in struct siginfo are done properly
and then calls send_sig_info.

In short about a 5 line reduction in code for every time send_sig_info
is called, which makes the calling function clearer.

Cc: Richard Henderson <rth@twiddle.net>
Cc: Ivan Kokshaysky <ink@jurassic.park.msu.ru>
Cc: linux-alpha@vger.kernel.org
Signed-off-by: default avatar"Eric W. Biederman" <ebiederm@xmission.com>
parent e821fa42
Loading
Loading
Loading
Loading
+3 −7
Original line number Diff line number Diff line
@@ -871,7 +871,6 @@ SYSCALL_DEFINE5(osf_setsysinfo, unsigned long, op, void __user *, buffer,
		   send a signal.  Old exceptions are not signaled.  */
		fex = (exc >> IEEE_STATUS_TO_EXCSUM_SHIFT) & swcr;
 		if (fex) {
			siginfo_t info;
			int si_code = FPE_FLTUNK;

			if (fex & IEEE_TRAP_ENABLE_DNO) si_code = FPE_FLTUND;
@@ -881,12 +880,9 @@ SYSCALL_DEFINE5(osf_setsysinfo, unsigned long, op, void __user *, buffer,
			if (fex & IEEE_TRAP_ENABLE_DZE) si_code = FPE_FLTDIV;
			if (fex & IEEE_TRAP_ENABLE_INV) si_code = FPE_FLTINV;

			clear_siginfo(&info);
			info.si_signo = SIGFPE;
			info.si_errno = 0;
			info.si_code = si_code;
			info.si_addr = NULL;  /* FIXME */
 			send_sig_info(SIGFPE, &info, current);
			send_sig_fault(SIGFPE, si_code,
				       (void __user *)NULL,  /* FIXME */
				       0, current);
 		}
		return 0;
	}
+4 −18
Original line number Diff line number Diff line
@@ -219,15 +219,8 @@ do_sigreturn(struct sigcontext __user *sc)

	/* Send SIGTRAP if we're single-stepping: */
	if (ptrace_cancel_bpt (current)) {
		siginfo_t info;

		clear_siginfo(&info);
		info.si_signo = SIGTRAP;
		info.si_errno = 0;
		info.si_code = TRAP_BRKPT;
		info.si_addr = (void __user *) regs->pc;
		info.si_trapno = 0;
		send_sig_info(SIGTRAP, &info, current);
		send_sig_fault(SIGTRAP, TRAP_BRKPT, (void __user *) regs->pc, 0,
			       current);
	}
	return;

@@ -254,15 +247,8 @@ do_rt_sigreturn(struct rt_sigframe __user *frame)

	/* Send SIGTRAP if we're single-stepping: */
	if (ptrace_cancel_bpt (current)) {
		siginfo_t info;

		clear_siginfo(&info);
		info.si_signo = SIGTRAP;
		info.si_errno = 0;
		info.si_code = TRAP_BRKPT;
		info.si_addr = (void __user *) regs->pc;
		info.si_trapno = 0;
		send_sig_info(SIGTRAP, &info, current);
		send_sig_fault(SIGTRAP, TRAP_BRKPT, (void __user *) regs->pc, 0,
			       current);
	}
	return;

+17 −54
Original line number Diff line number Diff line
@@ -213,7 +213,6 @@ do_entArith(unsigned long summary, unsigned long write_mask,
	    struct pt_regs *regs)
{
	long si_code = FPE_FLTINV;
	siginfo_t info;

	if (summary & 1) {
		/* Software-completion summary bit is set, so try to
@@ -228,21 +227,14 @@ do_entArith(unsigned long summary, unsigned long write_mask,
	}
	die_if_kernel("Arithmetic fault", regs, 0, NULL);

	clear_siginfo(&info);
	info.si_signo = SIGFPE;
	info.si_errno = 0;
	info.si_code = si_code;
	info.si_addr = (void __user *) regs->pc;
	send_sig_info(SIGFPE, &info, current);
	send_sig_fault(SIGFPE, si_code, (void __user *) regs->pc, 0, current);
}

asmlinkage void
do_entIF(unsigned long type, struct pt_regs *regs)
{
	siginfo_t info;
	int signo, code;

	clear_siginfo(&info);
	if ((regs->ps & ~IPL_MAX) == 0) {
		if (type == 1) {
			const unsigned int *data
@@ -272,31 +264,20 @@ do_entIF(unsigned long type, struct pt_regs *regs)

	switch (type) {
	      case 0: /* breakpoint */
		info.si_signo = SIGTRAP;
		info.si_errno = 0;
		info.si_code = TRAP_BRKPT;
		info.si_trapno = 0;
		info.si_addr = (void __user *) regs->pc;

		if (ptrace_cancel_bpt(current)) {
			regs->pc -= 4;	/* make pc point to former bpt */
		}

		send_sig_info(SIGTRAP, &info, current);
		send_sig_fault(SIGTRAP, TRAP_BRKPT, (void __user *)regs->pc, 0,
			       current);
		return;

	      case 1: /* bugcheck */
		info.si_signo = SIGTRAP;
		info.si_errno = 0;
		info.si_code = TRAP_UNK;
		info.si_addr = (void __user *) regs->pc;
		info.si_trapno = 0;
		send_sig_info(SIGTRAP, &info, current);
		send_sig_fault(SIGTRAP, TRAP_UNK, (void __user *) regs->pc, 0,
			       current);
		return;
		
	      case 2: /* gentrap */
		info.si_addr = (void __user *) regs->pc;
		info.si_trapno = regs->r16;
		switch ((long) regs->r16) {
		case GEN_INTOVF:
			signo = SIGFPE;
@@ -354,11 +335,8 @@ do_entIF(unsigned long type, struct pt_regs *regs)
			break;
		}

		info.si_signo = signo;
		info.si_errno = 0;
		info.si_code = code;
		info.si_addr = (void __user *) regs->pc;
		send_sig_info(signo, &info, current);
		send_sig_fault(signo, code, (void __user *) regs->pc, regs->r16,
			       current);
		return;

	      case 4: /* opDEC */
@@ -382,11 +360,9 @@ do_entIF(unsigned long type, struct pt_regs *regs)
			if (si_code == 0)
				return;
			if (si_code > 0) {
				info.si_signo = SIGFPE;
				info.si_errno = 0;
				info.si_code = si_code;
				info.si_addr = (void __user *) regs->pc;
				send_sig_info(SIGFPE, &info, current);
				send_sig_fault(SIGFPE, si_code,
					       (void __user *) regs->pc, 0,
					       current);
				return;
			}
		}
@@ -411,11 +387,7 @@ do_entIF(unsigned long type, struct pt_regs *regs)
		      ;
	}

	info.si_signo = SIGILL;
	info.si_errno = 0;
	info.si_code = ILL_ILLOPC;
	info.si_addr = (void __user *) regs->pc;
	send_sig_info(SIGILL, &info, current);
	send_sig_fault(SIGILL, ILL_ILLOPC, (void __user *)regs->pc, 0, current);
}

/* There is an ifdef in the PALcode in MILO that enables a 
@@ -761,11 +733,9 @@ do_entUnaUser(void __user * va, unsigned long opcode,

	unsigned long tmp1, tmp2, tmp3, tmp4;
	unsigned long fake_reg, *reg_addr = &fake_reg;
	siginfo_t info;
	int si_code;
	long error;

	clear_siginfo(&info);

	/* Check the UAC bits to decide what the user wants us to do
	   with the unaliged access.  */

@@ -986,34 +956,27 @@ do_entUnaUser(void __user * va, unsigned long opcode,

give_sigsegv:
	regs->pc -= 4;  /* make pc point to faulting insn */
	info.si_signo = SIGSEGV;
	info.si_errno = 0;

	/* We need to replicate some of the logic in mm/fault.c,
	   since we don't have access to the fault code in the
	   exception handling return path.  */
	if ((unsigned long)va >= TASK_SIZE)
		info.si_code = SEGV_ACCERR;
		si_code = SEGV_ACCERR;
	else {
		struct mm_struct *mm = current->mm;
		down_read(&mm->mmap_sem);
		if (find_vma(mm, (unsigned long)va))
			info.si_code = SEGV_ACCERR;
			si_code = SEGV_ACCERR;
		else
			info.si_code = SEGV_MAPERR;
			si_code = SEGV_MAPERR;
		up_read(&mm->mmap_sem);
	}
	info.si_addr = va;
	send_sig_info(SIGSEGV, &info, current);
	send_sig_fault(SIGSEGV, si_code, va, 0, current);
	return;

give_sigbus:
	regs->pc -= 4;
	info.si_signo = SIGBUS;
	info.si_errno = 0;
	info.si_code = BUS_ADRALN;
	info.si_addr = va;
	send_sig_info(SIGBUS, &info, current);
	send_sig_fault(SIGBUS, BUS_ADRALN, va, 0, current);
	return;
}