The maximum value PA_SaveConfigTime is 250 (10us) but this is not enough for some vendors. Gear switch from PWM to HS may fail even with this max. PA_SaveConfigTime. Gear switch can be issued by host controller as an error recovery and any software delay will not help on this case so we need to increase PA_SaveConfigTime to >32us as per vendor recommendation. This change adds a quirk to increase the PA_SaveConfigTime parameter. Reviewed-by:Venkat Gopalakrishnan <venkatg@codeaurora.org> Signed-off-by:
Subhash Jadavani <subhashj@codeaurora.org> Signed-off-by:
Martin K. Petersen <martin.petersen@oracle.com>