Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 02c5dff5 authored by Peter Meerwald-Stadler's avatar Peter Meerwald-Stadler Committed by Jonathan Cameron
Browse files

dt-bindings: iio: health: Add MAX30105 support to max30102.txt



Signed-off-by: default avatarPeter Meerwald-Stadler <pmeerw@pmeerw.net>
Acked-by: default avatarMatt Ranostay <matt.ranostay@konsulko.com>
Cc: Rob Herring <robh+dt@kernel.org>
Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent 90579b69
Loading
Loading
Loading
Loading
+6 −2
Original line number Diff line number Diff line
Maxim MAX30102 heart rate and pulse oximeter sensor
Maxim MAX30105 optical particle-sensing module

* https://datasheets.maximintegrated.com/en/ds/MAX30102.pdf
* https://datasheets.maximintegrated.com/en/ds/MAX30105.pdf

Required properties:
  - compatible: must be "maxim,max30102"
  - compatible: must be "maxim,max30102" or "maxim,max30105"
  - reg: the I2C address of the sensor
  - interrupt-parent: should be the phandle for the interrupt controller
  - interrupts: the sole interrupt generated by the device
@@ -12,8 +14,10 @@ Required properties:
  interrupt client node bindings.

Optional properties:
  - maxim,red-led-current-microamp: configuration for RED LED current
  - maxim,red-led-current-microamp: configuration for red LED current
  - maxim,ir-led-current-microamp: configuration for IR LED current
  - maxim,green-led-current-microamp: configuration for green LED current
    (max30105 only)

    Note that each step is approximately 200 microamps, ranging from 0 uA to
    50800 uA.