Commit d9f903f6 authored by Heiner Kallweit's avatar Heiner Kallweit Committed by David S. Miller
Browse files

net: phy: fix too strict check in phy_start_aneg



When adding checks to detect wrong usage of the phylib API we added
a check to phy_start_aneg() which is too strict. If the phylib
state machine is in state PHY_HALTED we should allow reconfiguring
and restarting aneg, and just don't touch the state.

Fixes: 2b3e88ea ("net: phy: improve phy state checking")
Reported-by: default avatarChris Wilson <chris@chris-wilson.co.uk>
Signed-off-by: default avatarHeiner Kallweit <hkallweit1@gmail.com>
Tested-by: default avatarChris Wilson <chris@chris-wilson.co.uk>
Reviewed-by: default avatarFlorian Fainelli <f.fainelli@gmail.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 5642e27b
Loading
Loading
Loading
Loading
+7 −12
Original line number Diff line number Diff line
@@ -543,13 +543,6 @@ int phy_start_aneg(struct phy_device *phydev)

	mutex_lock(&phydev->lock);

	if (!__phy_is_started(phydev)) {
		WARN(1, "called from state %s\n",
		     phy_state_to_str(phydev->state));
		err = -EBUSY;
		goto out_unlock;
	}

	if (AUTONEG_DISABLE == phydev->autoneg)
		phy_sanitize_settings(phydev);

@@ -560,12 +553,14 @@ int phy_start_aneg(struct phy_device *phydev)
	if (err < 0)
		goto out_unlock;

	if (__phy_is_started(phydev)) {
		if (phydev->autoneg == AUTONEG_ENABLE) {
			err = phy_check_link_status(phydev);
		} else {
			phydev->state = PHY_FORCING;
			phydev->link_timeout = PHY_FORCE_TIMEOUT;
		}
	}

out_unlock:
	mutex_unlock(&phydev->lock);