Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit a4710b72 authored by Mauro Carvalho Chehab's avatar Mauro Carvalho Chehab Committed by Guenter Roeck
Browse files

docs: hwmon: ibmpowernv: convert to ReST format



Convert ibmpowernv to ReST format, in order to allow it to
be parsed by Sphinx.

Signed-off-by: default avatarMauro Carvalho Chehab <mchehab+samsung@kernel.org>
Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 9e929c67
Loading
Loading
Loading
Loading
+19 −12
Original line number Diff line number Diff line
@@ -2,6 +2,7 @@ Kernel Driver IBMPOWERNV
========================

Supported systems:

  * Any recent IBM P servers based on POWERNV platform

Author: Neelesh Gupta
@@ -29,10 +30,11 @@ CONFIG_SENSORS_IBMPOWERNV. It can also be built as module 'ibmpowernv'.
Sysfs attributes
----------------

======================= =======================================================
fanX_input		Measured RPM value.
fanX_min		Threshold RPM for alert generation.
fanX_fault		0: No fail condition
			1: Failing fan
fanX_fault		- 0: No fail condition
			- 1: Failing fan

tempX_input		Measured ambient temperature.
tempX_max		Threshold ambient temperature for alert generation.
@@ -42,20 +44,22 @@ tempX_enable Enable/disable all temperature sensors belonging to the
			sub-group. In POWER9, this attribute corresponds to
			each OCC. Using this attribute each OCC can be asked to
			disable/enable all of its temperature sensors.
			1: Enable
			0: Disable

			- 1: Enable
			- 0: Disable

inX_input		Measured power supply voltage (millivolt)
inX_fault		0: No fail condition.
			1: Failing power supply.
inX_fault		- 0: No fail condition.
			- 1: Failing power supply.
inX_highest		Historical maximum voltage
inX_lowest		Historical minimum voltage
inX_enable		Enable/disable all voltage sensors belonging to the
			sub-group. In POWER9, this attribute corresponds to
			each OCC. Using this attribute each OCC can be asked to
			disable/enable all of its voltage sensors.
			1: Enable
			0: Disable

			- 1: Enable
			- 0: Disable

powerX_input		Power consumption (microWatt)
powerX_input_highest	Historical maximum power
@@ -64,8 +68,9 @@ powerX_enable Enable/disable all power sensors belonging to the
			sub-group. In POWER9, this attribute corresponds to
			each OCC. Using this attribute each OCC can be asked to
			disable/enable all of its power sensors.
			1: Enable
			0: Disable

			- 1: Enable
			- 0: Disable

currX_input		Measured current (milliampere)
currX_highest		Historical maximum current
@@ -74,7 +79,9 @@ currX_enable Enable/disable all current sensors belonging to the
			sub-group. In POWER9, this attribute corresponds to
			each OCC. Using this attribute each OCC can be asked to
			disable/enable all of its current sensors.
			1: Enable
			0: Disable

			- 1: Enable
			- 0: Disable

energyX_input		Cumulative energy (microJoule)
======================= =======================================================