regulator: of: Use of_property_read_u32() for reading min/max



OF interface provides to read the u32 value via standard interface
of_property_read_u32(). Use this API to read "regulator-min-microvolts"
and "regulator-max-microvolt".

This will make consistent with other property value reads.

Signed-off-by: default avatarLaxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: default avatarMark Brown <broonie@kernel.org>
parent 92e963f5
Loading
Loading
Loading
Loading
+7 −8
Original line number Diff line number Diff line
@@ -28,7 +28,6 @@ static void of_get_regulation_constraints(struct device_node *np,
					struct regulator_init_data **init_data,
					const struct regulator_desc *desc)
{
	const __be32 *min_uV, *max_uV;
	struct regulation_constraints *constraints = &(*init_data)->constraints;
	struct regulator_state *suspend_state;
	struct device_node *suspend_np;
@@ -37,18 +36,18 @@ static void of_get_regulation_constraints(struct device_node *np,

	constraints->name = of_get_property(np, "regulator-name", NULL);

	min_uV = of_get_property(np, "regulator-min-microvolt", NULL);
	if (min_uV)
		constraints->min_uV = be32_to_cpu(*min_uV);
	max_uV = of_get_property(np, "regulator-max-microvolt", NULL);
	if (max_uV)
		constraints->max_uV = be32_to_cpu(*max_uV);
	if (!of_property_read_u32(np, "regulator-min-microvolt", &pval))
		constraints->min_uV = pval;

	if (!of_property_read_u32(np, "regulator-max-microvolt", &pval))
		constraints->max_uV = pval;

	/* Voltage change possible? */
	if (constraints->min_uV != constraints->max_uV)
		constraints->valid_ops_mask |= REGULATOR_CHANGE_VOLTAGE;
	/* Only one voltage?  Then make sure it's set. */
	if (min_uV && max_uV && constraints->min_uV == constraints->max_uV)
	if (constraints->min_uV && constraints->max_uV &&
	    constraints->min_uV == constraints->max_uV)
		constraints->apply_uV = true;

	if (!of_property_read_u32(np, "regulator-microvolt-offset", &pval))