Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 7e798ef9 authored by William Breathitt Gray's avatar William Breathitt Gray Committed by Greg Kroah-Hartman
Browse files

counter: 104-quad-8: Documentation: Add Generic Counter sysfs documentation



This patch adds standard documentation for the Generic Counter interface
userspace sysfs attributes of the 104-QUAD-8 driver.

Acked-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: default avatarWilliam Breathitt Gray <vilhelm.gray@gmail.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent f1d8a071
Loading
Loading
Loading
Loading
+36 −0
Original line number Diff line number Diff line
What:		/sys/bus/counter/devices/counterX/signalY/index_polarity
KernelVersion:	5.2
Contact:	linux-iio@vger.kernel.org
Description:
		Active level of index input Signal Y; irrelevant in
		non-synchronous load mode.

What:		/sys/bus/counter/devices/counterX/signalY/index_polarity_available
What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
KernelVersion:	5.2
Contact:	linux-iio@vger.kernel.org
Description:
		Discrete set of available values for the respective Signal Y
		configuration are listed in this file.

What:		/sys/bus/counter/devices/counterX/signalY/synchronous_mode
KernelVersion:	5.2
Contact:	linux-iio@vger.kernel.org
Description:
		Configure the counter associated with Signal Y for
		non-synchronous or synchronous load mode. Synchronous load mode
		cannot be selected in non-quadrature (Pulse-Direction) clock
		mode.

		non-synchronous:
			A logic low level is the active level at this index
			input. The index function (as enabled via preset_enable)
			is performed directly on the active level of the index
			input.

		synchronous:
			Intended for interfacing with encoder Index output in
			quadrature clock mode. The active level is configured
			via index_polarity. The index function (as enabled via
			preset_enable) is performed synchronously with the
			quadrature clock on the active level of the index input.
+1 −0
Original line number Diff line number Diff line
@@ -272,6 +272,7 @@ ACCES 104-QUAD-8 DRIVER
M:	William Breathitt Gray <vilhelm.gray@gmail.com>
L:	linux-iio@vger.kernel.org
S:	Maintained
F:	Documentation/ABI/testing/sysfs-bus-counter-104-quad-8
F:	Documentation/ABI/testing/sysfs-bus-iio-counter-104-quad-8
F:	drivers/counter/104-quad-8.c