mlxsw: cmd: Update CONFIG_PROFILE command documentation



The meaning of certain parameters in the profile passed to the device
during initialization has changed, so update their documentation
accordingly.

Signed-off-by: default avatarIdo Schimmel <idosch@mellanox.com>
Signed-off-by: default avatarJiri Pirko <jiri@mellanox.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 801bd3de
Loading
Loading
Loading
Loading
+11 −13
Original line number Diff line number Diff line
@@ -570,7 +570,7 @@ MLXSW_ITEM32(cmd_mbox, config_profile, set_max_vlan_groups, 0x0C, 6, 1);
 */
MLXSW_ITEM32(cmd_mbox, config_profile, set_max_regions, 0x0C, 7, 1);

/* cmd_mbox_config_profile_set_fid_based
/* cmd_mbox_config_profile_set_flood_mode
 * Capability bit. Setting a bit to 1 configures the profile
 * according to the mailbox contents.
 */
@@ -651,12 +651,8 @@ MLXSW_ITEM32(cmd_mbox, config_profile, max_vlan_groups, 0x28, 0, 12);
MLXSW_ITEM32(cmd_mbox, config_profile, max_regions, 0x2C, 0, 16);

/* cmd_mbox_config_profile_max_flood_tables
 * Maximum number of Flooding Tables. Flooding Tables are associated to
 * the different packet types for the different switch partitions.
 * Note that the table size depends on the fid_based mode.
 * In SwitchX silicon, tables are split equally between the switch
 * partitions. e.g. for 2 swids and 8 tables, the first 4 are associated
 * with swid-1 and the last 4 are associated with swid-2.
 * Maximum number of single-entry flooding tables. Different flooding tables
 * can be associated with different packet types.
 */
MLXSW_ITEM32(cmd_mbox, config_profile, max_flood_tables, 0x30, 16, 4);

@@ -667,12 +663,14 @@ MLXSW_ITEM32(cmd_mbox, config_profile, max_flood_tables, 0x30, 16, 4);
 */
MLXSW_ITEM32(cmd_mbox, config_profile, max_vid_flood_tables, 0x30, 8, 4);

/* cmd_mbox_config_profile_fid_based
 * FID Based Flood Mode
 * 00 Do not use FID to offset the index into the Port Group Table/Multicast ID
 * 01 Use FID to offset the index to the Port Group Table (pgi)
 * 10 Use FID to offset the index to the Port Group Table (pgi) and
 * the Multicast ID
/* cmd_mbox_config_profile_flood_mode
 * Flooding mode to use.
 * 0-2 - Backward compatible modes for SwitchX devices.
 * 3 - Mixed mode, where:
 * max_flood_tables indicates the number of single-entry tables.
 * max_vid_flood_tables indicates the number of per-VID tables.
 * max_fid_offset_flood_tables indicates the number of FID-offset tables.
 * max_fid_flood_tables indicates the number of per-FID tables.
 */
MLXSW_ITEM32(cmd_mbox, config_profile, flood_mode, 0x30, 0, 2);