Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Unverified Commit 4f297062 authored by Axel Lin's avatar Axel Lin Committed by Mark Brown
Browse files

regulator: rk808: Convert rk805 buck1/2 to use linear range



It looks like linear range is suitable to describe the voltage table
for rk805 buck1/2:

selector 0 ~ 59: 0.7125V with uV_step = 12500
selector 60 ~ 62: 1.8V with uV_step = 200000
selector 63: 2.3V

With this change, then rk805 buck1/2 can reuse rk808_reg_ops_ranges.

Signed-off-by: default avatarAxel Lin <axel.lin@ingics.com>
Tested-by: default avatarOtavio Salvador <otavio@ossystems.com.br>
Signed-off-by: default avatarMark Brown <broonie@kernel.org>
parent 46689b1e
Loading
Loading
Loading
Loading
+12 −43
Original line number Diff line number Diff line
@@ -289,21 +289,6 @@ static int rk808_set_ramp_delay(struct regulator_dev *rdev, int ramp_delay)
				  RK808_RAMP_RATE_MASK, ramp_value);
}

static int rk805_set_suspend_voltage(struct regulator_dev *rdev, int uv)
{
	unsigned int reg;
	int sel = regulator_map_voltage_ascend(rdev, uv, uv);

	if (sel < 0)
		return -EINVAL;

	reg = rdev->desc->vsel_reg + RK808_SLP_REG_OFFSET;

	return regmap_update_bits(rdev->regmap, reg,
				  rdev->desc->vsel_mask,
				  sel);
}

static int rk808_set_suspend_voltage(struct regulator_dev *rdev, int uv)
{
	unsigned int reg;
@@ -399,19 +384,6 @@ static const struct regulator_ops rk805_switch_ops = {
	.set_suspend_disable    = rk805_set_suspend_disable,
};

static struct regulator_ops rk805_buck1_2_ops = {
		.list_voltage		= regulator_list_voltage_table,
		.map_voltage		= regulator_map_voltage_ascend,
		.get_voltage_sel        = regulator_get_voltage_sel_regmap,
		.set_voltage_sel        = regulator_set_voltage_sel_regmap,
		.enable                 = regulator_enable_regmap,
		.disable                = regulator_disable_regmap,
		.is_enabled             = regulator_is_enabled_regmap,
		.set_suspend_voltage    = rk805_set_suspend_voltage,
		.set_suspend_enable     = rk805_set_suspend_enable,
		.set_suspend_disable    = rk805_set_suspend_disable,
};

static const struct regulator_ops rk808_buck1_2_ops = {
	.list_voltage		= regulator_list_voltage_linear,
	.map_voltage		= regulator_map_voltage_linear,
@@ -461,15 +433,10 @@ static const struct regulator_ops rk808_switch_ops = {
	.set_suspend_disable	= rk808_set_suspend_disable,
};

static const int rk805_buck_1_2_voltages[] = {
	712500, 725000, 737500, 750000, 762500, 775000, 787500, 800000,
	812500, 825000, 837500, 850000, 862500, 875000, 887500, 900000,
	912500, 925000, 937500, 950000, 962500, 975000, 987500, 1000000,
	1012500, 1025000, 1037500, 1050000, 1062500, 1075000, 1087500, 1100000,
	1112500, 1125000, 1137500, 1150000, 1162500, 1175000, 1187500, 1200000,
	1212500, 1225000, 1237500, 1250000, 1262500, 1275000, 1287500, 1300000,
	1312500, 1325000, 1337500, 1350000, 1362500, 1375000, 1387500, 1400000,
	1412500, 1425000, 1437500, 1450000, 1800000, 2000000, 2200000, 2300000,
static const struct regulator_linear_range rk805_buck_1_2_voltage_ranges[] = {
	REGULATOR_LINEAR_RANGE(712500, 0, 59, 12500),
	REGULATOR_LINEAR_RANGE(1800000, 60, 62, 200000),
	REGULATOR_LINEAR_RANGE(2300000, 63, 63, 0),
};

static const struct regulator_desc rk805_reg[] = {
@@ -479,10 +446,11 @@ static const struct regulator_desc rk805_reg[] = {
		.of_match = of_match_ptr("DCDC_REG1"),
		.regulators_node = of_match_ptr("regulators"),
		.id = RK805_ID_DCDC1,
		.ops = &rk805_buck1_2_ops,
		.ops = &rk808_reg_ops_ranges,
		.type = REGULATOR_VOLTAGE,
		.n_voltages = ARRAY_SIZE(rk805_buck_1_2_voltages),
		.volt_table = rk805_buck_1_2_voltages,
		.n_voltages = 64,
		.linear_ranges = rk805_buck_1_2_voltage_ranges,
		.n_linear_ranges = ARRAY_SIZE(rk805_buck_1_2_voltage_ranges),
		.vsel_reg = RK805_BUCK1_ON_VSEL_REG,
		.vsel_mask = RK818_BUCK_VSEL_MASK,
		.enable_reg = RK805_DCDC_EN_REG,
@@ -494,10 +462,11 @@ static const struct regulator_desc rk805_reg[] = {
		.of_match = of_match_ptr("DCDC_REG2"),
		.regulators_node = of_match_ptr("regulators"),
		.id = RK805_ID_DCDC2,
		.ops = &rk805_buck1_2_ops,
		.ops = &rk808_reg_ops_ranges,
		.type = REGULATOR_VOLTAGE,
		.n_voltages = ARRAY_SIZE(rk805_buck_1_2_voltages),
		.volt_table = rk805_buck_1_2_voltages,
		.n_voltages = 64,
		.linear_ranges = rk805_buck_1_2_voltage_ranges,
		.n_linear_ranges = ARRAY_SIZE(rk805_buck_1_2_voltage_ranges),
		.vsel_reg = RK805_BUCK2_ON_VSEL_REG,
		.vsel_mask = RK818_BUCK_VSEL_MASK,
		.enable_reg = RK805_DCDC_EN_REG,