Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 08c6df97 authored by Sebastian Ott's avatar Sebastian Ott Committed by Martin Schwidefsky
Browse files

s390/cmf: use tod_to_ns()



Instead of open coding tod clock to ns conversions use the timex helper.

Signed-off-by: default avatarSebastian Ott <sebott@linux.vnet.ibm.com>
Reviewed-by: default avatarPeter Oberparleiter <oberpar@linux.vnet.ibm.com>
Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
parent cb09b356
Loading
Loading
Loading
Loading
+3 −5
Original line number Diff line number Diff line
@@ -685,8 +685,7 @@ static int readall_cmb(struct ccw_device *cdev, struct cmbdata *data)
	/* we only know values before device_busy_time */
	data->size = offsetof(struct cmbdata, device_busy_time);

	/* convert to nanoseconds */
	data->elapsed_time = (time * 1000) >> 12;
	data->elapsed_time = tod_to_ns(time);

	/* copy data to new structure */
	data->ssch_rsch_count = cmb->ssch_rsch_count;
@@ -945,8 +944,7 @@ static int readall_cmbe(struct ccw_device *cdev, struct cmbdata *data)
	/* we only know values before device_busy_time */
	data->size = offsetof(struct cmbdata, device_busy_time);

	/* conver to nanoseconds */
	data->elapsed_time = (time * 1000) >> 12;
	data->elapsed_time = tod_to_ns(time);

	cmb = cmb_data->last_block;
	/* copy data to new structure */
@@ -1007,7 +1005,7 @@ static ssize_t cmb_show_avg_sample_interval(struct device *dev,
	spin_lock_irq(cdev->ccwlock);
	if (count) {
		interval = get_tod_clock() - cdev->private->cmb_start_time;
		interval = (interval * 1000) >> 12;
		interval = tod_to_ns(interval);
		interval /= count;
	} else
		interval = -1;