Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit f747a1fe authored by Lee Jones's avatar Lee Jones Committed by Mark Brown
Browse files

regulator: pwm-regulator: Remove obsoleted property



In "[3d7ef30] regulator: pwm-regulator: Simplify voltage to duty-cycle
call" we stopped using max_duty_cycle, so we can retire it from device
data and DT.

There is no need to deprecate this property, as it hasn't hit Mainline
yet.

Signed-off-by: default avatarLee Jones <lee.jones@linaro.org>
Signed-off-by: default avatarMark Brown <broonie@kernel.org>
parent a505bfb1
Loading
Loading
Loading
Loading
+4 −7
Original line number Diff line number Diff line
@@ -29,15 +29,14 @@ Required properties:

- pwms:			PWM specification (See: ../pwm/pwm.txt)

One of these must be provided:
Only required for Voltage Table Mode:
- voltage-table: 	Voltage and Duty-Cycle table consisting of 2 cells
			    First cell is voltage in microvolts (uV)
			    Second cell is duty-cycle in percent (%)

- max-duty-cycle:	Maximum Duty-Cycle value -- this will normally be
  			255 (0xff) for an 8 bit PWM device

If both are provided, the current default is voltage-table mode.
NB: To be clear, if voltage-table is provided, then the device will be used
in Voltage Table Mode.  If no voltage-table is provided, then the device will
be used in Continuous Voltage Mode.

Any property defined as part of the core regulator binding can also be used.
(See: ../regulator/regulator.txt)
@@ -49,8 +48,6 @@ Continuous Voltage Example:
		regulator-min-microvolt = <1016000>;
		regulator-max-microvolt = <1114000>;
		regulator-name = "vdd_logic";

		max-duty-cycle = <255>; /* 8bit PWM */
	};

Voltage Table Example:
+0 −9
Original line number Diff line number Diff line
@@ -30,7 +30,6 @@ struct pwm_regulator_data {
	int state;

	/* Continuous voltage */
	u32 max_duty_cycle;
	int volt_uV;
};

@@ -201,14 +200,6 @@ static int pwm_regulator_init_continuous(struct platform_device *pdev,
					 struct pwm_regulator_data *drvdata)
{
	struct device_node *np = pdev->dev.of_node;
	int ret;

	ret = of_property_read_u32(np, "max-duty-cycle",
				   &drvdata->max_duty_cycle);
	if (ret) {
		dev_err(&pdev->dev, "Failed to read \"pwm-max-value\"\n");
		return ret;
	}

	pwm_regulator_desc.ops = &pwm_regulator_voltage_continuous_ops;
	pwm_regulator_desc.continuous_voltage_range = true;