[PATCH] powerpc: Make sure we have an RTC before trying to adjust it



Its valid for ppc_md.set_rtc_time to be NULL.  We need to check
that its non-NULL before trying to update the RTC.

Signed-off-by: default avatarKumar K. Gala <kumar.gala@freescale.com>
Signed-off-by: default avatarPaul Mackerras <paulus@samba.org>
parent 34060104
Loading
Loading
Loading
Loading
+1 −1
Original line number Diff line number Diff line
@@ -154,7 +154,7 @@ static __inline__ void timer_check_rtc(void)
         * We should have an rtc call that only sets the minutes and
         * seconds like on Intel to avoid problems with non UTC clocks.
         */
        if (ntp_synced() &&
        if (ppc_md.set_rtc_time && ntp_synced() &&
	    xtime.tv_sec - last_rtc_update >= 659 &&
	    abs((xtime.tv_nsec/1000) - (1000000-1000000/HZ)) < 500000/HZ &&