Loading bindings/power/supply/qcom/qpnp-fg-gen4.txt +6 −6 Original line number Diff line number Diff line Loading @@ -359,7 +359,7 @@ First Level Node - FG Gen4 device property should be specified if qcom,ki-coeff-soc-dischg is specified to make it fully functional. Value has no unit. Allowed range is 0 to 15564 in micro units. If this is not specified, the default value used will be 122. is not specified, the default value used will be 367. - qcom,ki-coeff-med-dischg Usage: optional Loading Loading @@ -410,7 +410,7 @@ First Level Node - FG Gen4 device Definition: ki coefficient value for low charge current during charging. Value has no unit. Allowed range is 0 to 15564 in micro units. If this is not specified, the default value used will be 183. used will be 184. - qcom,ki-coeff-med-chg Usage: optional Loading @@ -435,8 +435,8 @@ First Level Node - FG Gen4 device coefficient will be applied: qcom,ki-coeff-low-chg if the threshold is not breached, and qcom,ki-coeff-med-chg otherwise. Allowed range is 0 to 3984 milliamperes. If this is not specified, the default value used will be 1000 (1000 mA). is not specified, the default value used will be 500 (500 mA). - qcom,ki-coeff-chg-med-hi-thresh-ma Usage: optional Loading @@ -445,8 +445,8 @@ First Level Node - FG Gen4 device coefficient will be applied: qcom,ki-coeff-med-chg if the threshold is not breached, and qcom,ki-coeff-hi-chg otherwise. Allowed range is 0 to 3984 milliamperes. If this is not specified, the default value used will be 1500 (1500 mA). is not specified, the default value used will be 1000 (1000 mA). - qcom,ki-coeff-cutoff Usage: optional Loading Loading
bindings/power/supply/qcom/qpnp-fg-gen4.txt +6 −6 Original line number Diff line number Diff line Loading @@ -359,7 +359,7 @@ First Level Node - FG Gen4 device property should be specified if qcom,ki-coeff-soc-dischg is specified to make it fully functional. Value has no unit. Allowed range is 0 to 15564 in micro units. If this is not specified, the default value used will be 122. is not specified, the default value used will be 367. - qcom,ki-coeff-med-dischg Usage: optional Loading Loading @@ -410,7 +410,7 @@ First Level Node - FG Gen4 device Definition: ki coefficient value for low charge current during charging. Value has no unit. Allowed range is 0 to 15564 in micro units. If this is not specified, the default value used will be 183. used will be 184. - qcom,ki-coeff-med-chg Usage: optional Loading @@ -435,8 +435,8 @@ First Level Node - FG Gen4 device coefficient will be applied: qcom,ki-coeff-low-chg if the threshold is not breached, and qcom,ki-coeff-med-chg otherwise. Allowed range is 0 to 3984 milliamperes. If this is not specified, the default value used will be 1000 (1000 mA). is not specified, the default value used will be 500 (500 mA). - qcom,ki-coeff-chg-med-hi-thresh-ma Usage: optional Loading @@ -445,8 +445,8 @@ First Level Node - FG Gen4 device coefficient will be applied: qcom,ki-coeff-med-chg if the threshold is not breached, and qcom,ki-coeff-hi-chg otherwise. Allowed range is 0 to 3984 milliamperes. If this is not specified, the default value used will be 1500 (1500 mA). is not specified, the default value used will be 1000 (1000 mA). - qcom,ki-coeff-cutoff Usage: optional Loading