Loading drivers/scsi/hpsa.c +10 −0 Original line number Diff line number Diff line Loading @@ -119,6 +119,11 @@ static const struct pci_device_id hpsa_pci_device_id[] = { {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSI, 0x103C, 0x21C7}, {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSI, 0x103C, 0x21C8}, {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSI, 0x103C, 0x21C9}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0076}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0087}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x007D}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0088}, {PCI_VENDOR_ID_HP, 0x333f, 0x103c, 0x333f}, {PCI_VENDOR_ID_HP, PCI_ANY_ID, PCI_ANY_ID, PCI_ANY_ID, PCI_CLASS_STORAGE_RAID << 8, 0xffff << 8, 0}, {0,} Loading Loading @@ -164,6 +169,11 @@ static struct board_type products[] = { {0x21C7103C, "Smart Array", &SA5_access}, {0x21C8103C, "Smart Array", &SA5_access}, {0x21C9103C, "Smart Array", &SA5_access}, {0x00761590, "HP Storage P1224 Array Controller", &SA5_access}, {0x00871590, "HP Storage P1224e Array Controller", &SA5_access}, {0x007D1590, "HP Storage P1228 Array Controller", &SA5_access}, {0x00881590, "HP Storage P1228e Array Controller", &SA5_access}, {0x333f103c, "HP StorageWorks 1210m Array Controller", &SA5_access}, {0xFFFF103C, "Unknown Smart Array", &SA5_access}, }; Loading Loading
drivers/scsi/hpsa.c +10 −0 Original line number Diff line number Diff line Loading @@ -119,6 +119,11 @@ static const struct pci_device_id hpsa_pci_device_id[] = { {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSI, 0x103C, 0x21C7}, {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSI, 0x103C, 0x21C8}, {PCI_VENDOR_ID_HP, PCI_DEVICE_ID_HP_CISSI, 0x103C, 0x21C9}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0076}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0087}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x007D}, {PCI_VENDOR_ID_HP_3PAR, 0x0075, 0x1590, 0x0088}, {PCI_VENDOR_ID_HP, 0x333f, 0x103c, 0x333f}, {PCI_VENDOR_ID_HP, PCI_ANY_ID, PCI_ANY_ID, PCI_ANY_ID, PCI_CLASS_STORAGE_RAID << 8, 0xffff << 8, 0}, {0,} Loading Loading @@ -164,6 +169,11 @@ static struct board_type products[] = { {0x21C7103C, "Smart Array", &SA5_access}, {0x21C8103C, "Smart Array", &SA5_access}, {0x21C9103C, "Smart Array", &SA5_access}, {0x00761590, "HP Storage P1224 Array Controller", &SA5_access}, {0x00871590, "HP Storage P1224e Array Controller", &SA5_access}, {0x007D1590, "HP Storage P1228 Array Controller", &SA5_access}, {0x00881590, "HP Storage P1228e Array Controller", &SA5_access}, {0x333f103c, "HP StorageWorks 1210m Array Controller", &SA5_access}, {0xFFFF103C, "Unknown Smart Array", &SA5_access}, }; Loading