Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Skip to content
Commit 83417206 authored by Jason Gerecke's avatar Jason Gerecke Committed by Jiri Kosina
Browse files

HID: wacom: Queue events with missing type/serial data for later processing



Userspace expects to receive tool type and serial number information
for the active pen in the very first kernel report, if such data is
supported by the hardware. While this expectation is not an issue for
EMR devices, AES sensors will often send several packets worth of in-
range data before relaying type/serial data to the kernel. Sending this
data "late" can result in proximity-tracking issues by xf86-input-wacom,
or an inability to distinguish different pens by input-wacom.

Options for dealing with this situation include ignoring reports from
the tablet until we get the necessary data, or using the information
from the last-seen pen instead of the (eventual) real data. Neither
option is particularly attractive: the former results in truncated
strokes and the latter causes issues with switching between pens.

This commit instead opts to queue up events with missing information
until we receive a report which contains it. At that point, we can
update the driver's state variables (id[0] and serial[0]) and replay
the queued events.

Signed-off-by: default avatarJason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: default avatarBenjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: default avatarJiri Kosina <jkosina@suse.cz>
parent 99acedad
Loading