Commit 4bf6980d authored by Jean-Francois Remy's avatar Jean-Francois Remy Committed by David S. Miller
Browse files

neighbour: fix base_reachable_time(_ms) not effective immediatly when changed



When setting base_reachable_time or base_reachable_time_ms on a
specific interface through sysctl or netlink, the reachable_time
value is not updated.

This means that neighbour entries will continue to be updated using the
old value until it is recomputed in neigh_period_work (which
    recomputes the value every 300*HZ).
On systems with HZ equal to 1000 for instance, it means 5mins before
the change is effective.

This patch changes this behavior by recomputing reachable_time after
each set on base_reachable_time or base_reachable_time_ms.
The new value will become effective the next time the neighbour's timer
is triggered.

Changes are made in two places: the netlink code for set and the sysctl
handling code. For sysctl, I use a proc_handler. The ipv6 network
code does provide its own handler but it already refreshes
reachable_time correctly so it's not an issue.
Any other user of neighbour which provide its own handlers must
refresh reachable_time.

Signed-off-by: default avatarJean-Francois Remy <jeff@melix.org>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 3d125f9c
Loading
Loading
Loading
Loading
+44 −0
Original line number Diff line number Diff line
@@ -2043,6 +2043,12 @@ static int neightbl_set(struct sk_buff *skb, struct nlmsghdr *nlh)
			case NDTPA_BASE_REACHABLE_TIME:
				NEIGH_VAR_SET(p, BASE_REACHABLE_TIME,
					      nla_get_msecs(tbp[i]));
				/* update reachable_time as well, otherwise, the change will
				 * only be effective after the next time neigh_periodic_work
				 * decides to recompute it (can be multiple minutes)
				 */
				p->reachable_time =
					neigh_rand_reach_time(NEIGH_VAR(p, BASE_REACHABLE_TIME));
				break;
			case NDTPA_GC_STALETIME:
				NEIGH_VAR_SET(p, GC_STALETIME,
@@ -2921,6 +2927,31 @@ static int neigh_proc_dointvec_unres_qlen(struct ctl_table *ctl, int write,
	return ret;
}

static int neigh_proc_base_reachable_time(struct ctl_table *ctl, int write,
					  void __user *buffer,
					  size_t *lenp, loff_t *ppos)
{
	struct neigh_parms *p = ctl->extra2;
	int ret;

	if (strcmp(ctl->procname, "base_reachable_time") == 0)
		ret = neigh_proc_dointvec_jiffies(ctl, write, buffer, lenp, ppos);
	else if (strcmp(ctl->procname, "base_reachable_time_ms") == 0)
		ret = neigh_proc_dointvec_ms_jiffies(ctl, write, buffer, lenp, ppos);
	else
		ret = -1;

	if (write && ret == 0) {
		/* update reachable_time as well, otherwise, the change will
		 * only be effective after the next time neigh_periodic_work
		 * decides to recompute it
		 */
		p->reachable_time =
			neigh_rand_reach_time(NEIGH_VAR(p, BASE_REACHABLE_TIME));
	}
	return ret;
}

#define NEIGH_PARMS_DATA_OFFSET(index)	\
	(&((struct neigh_parms *) 0)->data[index])

@@ -3047,6 +3078,19 @@ int neigh_sysctl_register(struct net_device *dev, struct neigh_parms *p,
		t->neigh_vars[NEIGH_VAR_RETRANS_TIME_MS].proc_handler = handler;
		/* ReachableTime (in milliseconds) */
		t->neigh_vars[NEIGH_VAR_BASE_REACHABLE_TIME_MS].proc_handler = handler;
	} else {
		/* Those handlers will update p->reachable_time after
		 * base_reachable_time(_ms) is set to ensure the new timer starts being
		 * applied after the next neighbour update instead of waiting for
		 * neigh_periodic_work to update its value (can be multiple minutes)
		 * So any handler that replaces them should do this as well
		 */
		/* ReachableTime */
		t->neigh_vars[NEIGH_VAR_BASE_REACHABLE_TIME].proc_handler =
			neigh_proc_base_reachable_time;
		/* ReachableTime (in milliseconds) */
		t->neigh_vars[NEIGH_VAR_BASE_REACHABLE_TIME_MS].proc_handler =
			neigh_proc_base_reachable_time;
	}

	/* Don't export sysctls to unprivileged users */