Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 35897b92 authored by Christoph Hellwig's avatar Christoph Hellwig
Browse files

nvme-fabrics: fix and refine state checks in __nvmf_check_ready



 - make sure we only allow internally generates commands in any non-live
   state
 - only allow connect commands on non-live queues when actually in the
   new or connecting states
 - treat all other non-live, non-dead states the same as a default
   cach-all

This fixes a regression where we could not shutdown a controller
orderly as we didn't allow the internal generated Property Set
command, and also ensures we don't accidentally let a Connect command
through in the wrong state.

Signed-off-by: default avatarChristoph Hellwig <hch@lst.de>
Reviewed-by: default avatarJames Smart <james.smart@broadcom.com>
parent 278ab379
Loading
Loading
Loading
Loading
+19 −20
Original line number Diff line number Diff line
@@ -556,34 +556,33 @@ EXPORT_SYMBOL_GPL(nvmf_fail_nonready_command);
bool __nvmf_check_ready(struct nvme_ctrl *ctrl, struct request *rq,
		bool queue_live)
{
	struct nvme_command *cmd = nvme_req(rq)->cmd;
	struct nvme_request *req = nvme_req(rq);

	switch (ctrl->state) {
	case NVME_CTRL_NEW:
	case NVME_CTRL_CONNECTING:
	case NVME_CTRL_DELETING:
	/*
		 * If queue is live, allow only commands that are internally
		 * generated pass through.  These are commands on the admin
		 * queue to initialize the controller. This will reject any
		 * ioctl admin cmds received while initializing.
	 * If we are in some state of setup or teardown only allow
	 * internally generated commands.
	 */
		if (queue_live && !(nvme_req(rq)->flags & NVME_REQ_USERCMD))
			return true;
	if (!blk_rq_is_passthrough(rq) || (req->flags & NVME_REQ_USERCMD))
		return false;

	/*
		 * If the queue is not live, allow only a connect command.  This
		 * will reject any ioctl admin cmd as well as initialization
		 * commands if the controller reverted the queue to non-live.
	 * Only allow commands on a live queue, except for the connect command,
	 * which is require to set the queue live in the appropinquate states.
	 */
		if (!queue_live && blk_rq_is_passthrough(rq) &&
		     cmd->common.opcode == nvme_fabrics_command &&
		     cmd->fabrics.fctype == nvme_fabrics_type_connect)
	switch (ctrl->state) {
	case NVME_CTRL_NEW:
	case NVME_CTRL_CONNECTING:
		if (req->cmd->common.opcode == nvme_fabrics_command &&
		    req->cmd->fabrics.fctype == nvme_fabrics_type_connect)
			return true;
		return false;
		break;
	default:
		break;
	case NVME_CTRL_DEAD:
		return false;
	}

	return queue_live;
}
EXPORT_SYMBOL_GPL(__nvmf_check_ready);