ath10k: fix some of the macro definitions of HTT_RX_IND message



Only five bits are defined to pass tid information in HTT_RX_IND
message, so the mask which can be used to extract tid should be 0x1f
instead of the current 0x3f. Also, macros which can be used to extract
flush_valid and release_valid bits have to be left shifted one bit less
because these information follow the tid right after. This patch does
not really fix anything functionally because these macros are not used
currently.

Signed-off-by: default avatarVasanthakumar Thiagarajan <vthiagar@qti.qualcomm.com>
Signed-off-by: default avatarKalle Valo <kvalo@qca.qualcomm.com>
parent 6847f967
Loading
Loading
Loading
Loading
+3 −3
Original line number Diff line number Diff line
@@ -485,10 +485,10 @@ struct htt_mgmt_tx_completion {
	__le32 status;
} __packed;

#define HTT_RX_INDICATION_INFO0_EXT_TID_MASK  (0x3F)
#define HTT_RX_INDICATION_INFO0_EXT_TID_MASK  (0x1F)
#define HTT_RX_INDICATION_INFO0_EXT_TID_LSB   (0)
#define HTT_RX_INDICATION_INFO0_FLUSH_VALID   (1 << 6)
#define HTT_RX_INDICATION_INFO0_RELEASE_VALID (1 << 7)
#define HTT_RX_INDICATION_INFO0_FLUSH_VALID   (1 << 5)
#define HTT_RX_INDICATION_INFO0_RELEASE_VALID (1 << 6)

#define HTT_RX_INDICATION_INFO1_FLUSH_START_SEQNO_MASK   0x0000003F
#define HTT_RX_INDICATION_INFO1_FLUSH_START_SEQNO_LSB    0