Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit b45bd1d7 authored by Tom Herbert's avatar Tom Herbert Committed by David S. Miller
Browse files

ip6_gre: Use correct flags for reading TUNNEL_SEQ



Fix two spots where o_flags in a tunnel are being compared to GRE_SEQ
instead of TUNNEL_SEQ.

Signed-off-by: default avatarTom Herbert <tom@herbertland.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 4b4a0c91
Loading
Loading
Loading
Loading
+2 −2
Original line number Diff line number Diff line
@@ -343,7 +343,7 @@ static struct ip6_tnl *ip6gre_tunnel_locate(struct net *net,
		goto failed_free;

	/* Can use a lockless transmit, unless we generate output sequences */
	if (!(nt->parms.o_flags & GRE_SEQ))
	if (!(nt->parms.o_flags & TUNNEL_SEQ))
		dev->features |= NETIF_F_LLTX;

	dev_hold(dev);
@@ -1314,7 +1314,7 @@ static int ip6gre_newlink(struct net *src_net, struct net_device *dev,
	dev->features		|= GRE6_FEATURES;
	dev->hw_features	|= GRE6_FEATURES;

	if (!(nt->parms.o_flags & GRE_SEQ)) {
	if (!(nt->parms.o_flags & TUNNEL_SEQ)) {
		/* TCP segmentation offload is not supported when we
		 * generate output sequences.
		 */