[SCSI] megaraid_sas: do not process cmds if hw_crit_error is set



Checks if hw_crit_error is set.
If it is set, we donot process commands.
Checks added in megasas_queue_command and command completion routines.

Signed-off-by: default avatarSumant Patro <sumant.patro@lsi.com>
Signed-off-by: default avatarJames Bottomley <James.Bottomley@SteelEye.com>
parent a9b73202
Loading
Loading
Loading
Loading
+12 −1
Original line number Diff line number Diff line
@@ -841,6 +841,11 @@ megasas_queue_command(struct scsi_cmnd *scmd, void (*done) (struct scsi_cmnd *))

	instance = (struct megasas_instance *)
	    scmd->device->host->hostdata;

	/* Don't process if we have already declared adapter dead */
	if (instance->hw_crit_error)
		return SCSI_MLQUEUE_HOST_BUSY;

	scmd->scsi_done = done;
	scmd->result = 0;

@@ -1282,11 +1287,13 @@ megasas_deplete_reply_queue(struct megasas_instance *instance, u8 alt_status)
	if(instance->instancet->clear_intr(instance->reg_set))
		return IRQ_NONE;

	if (instance->hw_crit_error)
		goto out_done;
        /*
	 * Schedule the tasklet for cmd completion
	 */
	tasklet_schedule(&instance->isr_tasklet);

out_done:
	return IRQ_HANDLED;
}

@@ -1741,6 +1748,10 @@ static void megasas_complete_cmd_dpc(unsigned long instance_addr)
	struct megasas_cmd *cmd;
	struct megasas_instance *instance = (struct megasas_instance *)instance_addr;

	/* If we have already declared adapter dead, donot complete cmds */
	if (instance->hw_crit_error)
		return;

	producer = *instance->producer;
	consumer = *instance->consumer;