Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 95677a9a authored by Srinivas Pandruvada's avatar Srinivas Pandruvada Committed by Rafael J. Wysocki
Browse files

PowerCap: Fix mode for energy counter



As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.

Signed-off-by: default avatarSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reported-by: default avatarDirk Brandewie <dirk.j.brandewie@intel.com>
Signed-off-by: default avatarRafael J. Wysocki <rafael.j.wysocki@intel.com>
parent 08ff4cbe
Loading
Loading
Loading
Loading
+6 −1
Original line number Diff line number Diff line
@@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
	if (power_zone->ops->get_max_energy_range_uj)
		power_zone->zone_dev_attrs[count++] =
					&dev_attr_max_energy_range_uj.attr;
	if (power_zone->ops->get_energy_uj)
	if (power_zone->ops->get_energy_uj) {
		if (power_zone->ops->reset_energy_uj)
			dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
		else
			dev_attr_energy_uj.attr.mode = S_IRUGO;
		power_zone->zone_dev_attrs[count++] =
					&dev_attr_energy_uj.attr;
	}
	if (power_zone->ops->get_power_uw)
		power_zone->zone_dev_attrs[count++] =
					&dev_attr_power_uw.attr;