Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 850b37a7 authored by Ivan T. Ivanov's avatar Ivan T. Ivanov Committed by Greg Kroah-Hartman
Browse files

tty: serial: msm: Remove 115.2 Kbps maximum baud rate limitation



UART controller is capable to perform transfers up to 4 Mbps.
Remove artificial 115.2 Kbps limitation.

Signed-off-by: default avatarIvan T. Ivanov <ivan.ivanov@linaro.org>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 99693945
Loading
Loading
Loading
Loading
+17 −3
Original line number Diff line number Diff line
@@ -882,6 +882,7 @@ msm_find_best_baud(struct uart_port *port, unsigned int baud)
		{    3, 0xdd,  8 },
		{    2, 0xee, 16 },
		{    1, 0xff, 31 },
		{    0, 0xff, 31 },
	};

	divisor = uart_get_divisor(port, baud);
@@ -893,16 +894,29 @@ msm_find_best_baud(struct uart_port *port, unsigned int baud)
	return entry; /* Default to smallest divider */
}

static int msm_set_baud_rate(struct uart_port *port, unsigned int baud)
static int msm_set_baud_rate(struct uart_port *port, unsigned int baud,
			     unsigned long *saved_flags)
{
	unsigned int rxstale, watermark, mask;
	struct msm_port *msm_port = UART_TO_MSM(port);
	const struct msm_baud_map *entry;
	unsigned long flags;

	entry = msm_find_best_baud(port, baud);

	msm_write(port, entry->code, UART_CSR);

	if (baud > 460800)
		port->uartclk = baud * 16;

	flags = *saved_flags;
	spin_unlock_irqrestore(&port->lock, flags);

	clk_set_rate(msm_port->clk, port->uartclk);

	spin_lock_irqsave(&port->lock, flags);
	*saved_flags = flags;

	/* RX stale watermark */
	rxstale = entry->rxstale;
	watermark = UART_IPR_STALE_LSB & rxstale;
@@ -1026,8 +1040,8 @@ static void msm_set_termios(struct uart_port *port, struct ktermios *termios,
		msm_stop_dma(port, dma);

	/* calculate and set baud rate */
	baud = uart_get_baud_rate(port, termios, old, 300, 115200);
	baud = msm_set_baud_rate(port, baud);
	baud = uart_get_baud_rate(port, termios, old, 300, 4000000);
	baud = msm_set_baud_rate(port, baud, &flags);
	if (tty_termios_baud_rate(termios))
		tty_termios_encode_baud_rate(termios, baud, baud);