[Camera]Fix Main camera can not work in SDM632

Correct the voltage from 1.2V to 1.175V

Root cause:
Vreg_L2 can not set to 1.2V

How to fix:
Set Voltage to 1.175V

Change-Id: I64aa39028230cdf88fe98c79f57a31d3c3eab52e
RiskArea:Main Camera
parent 79b6422f
Loading
Loading
Loading
Loading
+4 −4
Original line number Diff line number Diff line
@@ -44,8 +44,8 @@
		cam_vana-supply = <&pm8953_l22>;
		cam_v_custom1-supply = <&pm8953_l2>;
		qcom,cam-vreg-name = "cam_vana", "cam_v_custom1";
		qcom,cam-vreg-min-voltage = <2800000 1200000>;
		qcom,cam-vreg-max-voltage = <2800000 1200000>;
		qcom,cam-vreg-min-voltage = <2800000 1175000>;
		qcom,cam-vreg-max-voltage = <2800000 1175000>;
		qcom,cam-vreg-op-mode = <80000 105000>;
		pinctrl-names = "cam_default", "cam_suspend";
		pinctrl-0 = <&cam_sensor_mclk0_default &cam_sensor_rear_default>;
@@ -162,8 +162,8 @@
		cam_vana-supply = <&pm8953_l22>;
		cam_v_custom1-supply = <&pm8953_l2>;
		qcom,cam-vreg-name = "cam_vana", "cam_v_custom1";
		qcom,cam-vreg-min-voltage = <2800000 1200000>;
		qcom,cam-vreg-max-voltage = <2800000 1200000>;
		qcom,cam-vreg-min-voltage = <2800000 1175000>;
		qcom,cam-vreg-max-voltage = <2800000 1175000>;
		qcom,cam-vreg-op-mode = <80000 105000>;
		pinctrl-names = "cam_default", "cam_suspend";
		pinctrl-0 = <&cam_sensor_mclk0_default