Commit 6b2aa51d authored by Eduardo Valentin's avatar Eduardo Valentin Committed by Zhang Rui
Browse files

thermal: check for invalid trip setup when registering thermal device



This patch adds an extra check in the data structure while registering
a thermal device. The check is to avoid registering zones with a number
of trips greater than zero, but with no .get_trip_temp nor .get_trip_type
callbacks. Receiving such data structure may end in wrong data access.

Signed-off-by: default avatarEduardo Valentin <eduardo.valentin@ti.com>
Reviewed-by: default avatarDurgadoss R <durgadoss.r@intel.com>
Signed-off-by: default avatarZhang Rui <rui.zhang@intel.com>
parent 923e0b1e
Loading
Loading
Loading
Loading
+3 −0
Original line number Diff line number Diff line
@@ -1530,6 +1530,9 @@ struct thermal_zone_device *thermal_zone_device_register(const char *type,
	if (!ops || !ops->get_temp)
		return ERR_PTR(-EINVAL);

	if (trips > 0 && !ops->get_trip_type)
		return ERR_PTR(-EINVAL);

	tz = kzalloc(sizeof(struct thermal_zone_device), GFP_KERNEL);
	if (!tz)
		return ERR_PTR(-ENOMEM);