rtc: imxdi: add some background info about the states the machine can be in



Document the i.MX DryIce machine states.

Signed-off-by: default avatarJuergen Borleis <jbe@pengutronix.de>
Signed-off-by: default avatarRobert Schwebel <rsc@pengutronix.de>
[rsc: got NDA clearance from Freescale]
Signed-off-by: default avatarAlexandre Belloni <alexandre.belloni@free-electrons.com>
parent e30d3131
Loading
Loading
Loading
Loading
+43 −0
Original line number Original line Diff line number Diff line
@@ -129,6 +129,49 @@ struct imxdi_dev {
	struct work_struct work;
	struct work_struct work;
};
};


/* Some background:
 *
 * The DryIce unit is a complex security/tamper monitor device. To be able do
 * its job in a useful manner it runs a bigger statemachine to bring it into
 * security/tamper failure state and once again to bring it out of this state.
 *
 * This unit can be in one of three states:
 *
 * - "NON-VALID STATE"
 *   always after the battery power was removed
 * - "FAILURE STATE"
 *   if one of the enabled security events has happened
 * - "VALID STATE"
 *   if the unit works as expected
 *
 * Everything stops when the unit enters the failure state including the RTC
 * counter (to be able to detect the time the security event happened).
 *
 * The following events (when enabled) let the DryIce unit enter the failure
 * state:
 *
 * - wire-mesh-tamper detect
 * - external tamper B detect
 * - external tamper A detect
 * - temperature tamper detect
 * - clock tamper detect
 * - voltage tamper detect
 * - RTC counter overflow
 * - monotonic counter overflow
 * - external boot
 *
 * If we find the DryIce unit in "FAILURE STATE" and the TDCHL cleared, we
 * can only detect this state. In this case the unit is completely locked and
 * must force a second "SYSTEM POR" to bring the DryIce into the
 * "NON-VALID STATE" + "FAILURE STATE" where a recovery is possible.
 * If the TDCHL is set in the "FAILURE STATE" we are out of luck. In this case
 * a battery power cycle is required.
 *
 * In the "NON-VALID STATE" + "FAILURE STATE" we can clear the "FAILURE STATE"
 * and recover the DryIce unit. By clearing the "NON-VALID STATE" as the last
 * task, we bring back this unit into life.
 */

/*
/*
 * enable a dryice interrupt
 * enable a dryice interrupt
 */
 */