Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 1e8f86d9 authored by Rajkumar Manoharan's avatar Rajkumar Manoharan Committed by Kalle Valo
Browse files

ath10k: remove send completion validation in diag read/write



CE diag window access is serialized (it has to be by design) so
there's no way to get a different send completion. so there's no
need for post completion validation.

Signed-off-by: default avatarRajkumar Manoharan <rmanohar@qti.qualcomm.com>
Signed-off-by: default avatarKalle Valo <kvalo@qca.qualcomm.com>
parent b4e84c56
Loading
Loading
Loading
Loading
+0 −20
Original line number Diff line number Diff line
@@ -920,16 +920,6 @@ static int ath10k_pci_diag_read_mem(struct ath10k *ar, u32 address, void *data,
			}
		}

		if (nbytes != completed_nbytes) {
			ret = -EIO;
			goto done;
		}

		if (buf != (u32)address) {
			ret = -EIO;
			goto done;
		}

		i = 0;
		while (ath10k_ce_completed_recv_next_nolock(ce_diag, NULL, &buf,
							    &completed_nbytes,
@@ -1094,16 +1084,6 @@ static int ath10k_pci_diag_write_mem(struct ath10k *ar, u32 address,
			}
		}

		if (nbytes != completed_nbytes) {
			ret = -EIO;
			goto done;
		}

		if (buf != ce_data) {
			ret = -EIO;
			goto done;
		}

		i = 0;
		while (ath10k_ce_completed_recv_next_nolock(ce_diag, NULL, &buf,
							    &completed_nbytes,