powerpc/eeh: Block CFG upon frozen Shiner adapter



The Broadcom Shiner 2-ports 10G ethernet adapter has same problem
commit 6f20bda0 ("powerpc/eeh: Block PCI config access upon frozen
PE") fixes. Put it to the black list as well.

   # lspci -s 0004:01:00.0
   0004:01:00.0 Ethernet controller: Broadcom Corporation \
                NetXtreme II BCM57810 10 Gigabit Ethernet (rev 10)
   # lspci -n -s 0004:01:00.0
   0004:01:00.0 0200: 14e4:168e (rev 10)

Reported-by: default avatarJohn Walthour <jwalthour@us.ibm.com>
Signed-off-by: default avatarGavin Shan <gwshan@linux.vnet.ibm.com>
Signed-off-by: default avatarMichael Ellerman <mpe@ellerman.id.au>
parent c59004cc
Loading
Loading
Loading
Loading
+3 −2
Original line number Diff line number Diff line
@@ -182,9 +182,10 @@ static int powernv_eeh_dev_probe(struct pci_dev *dev, void *flag)
	 * that PE to block its config space.
	 *
	 * Broadcom Austin 4-ports NICs (14e4:1657)
	 * Broadcom Shiner 2-ports 10G NICs (14e4:168e)
	 */
	if (dev->vendor == PCI_VENDOR_ID_BROADCOM &&
	    dev->device == 0x1657)
	if ((dev->vendor == PCI_VENDOR_ID_BROADCOM && dev->device == 0x1657) ||
	    (dev->vendor == PCI_VENDOR_ID_BROADCOM && dev->device == 0x168e))
		edev->pe->state |= EEH_PE_CFG_RESTRICTED;

	/*