Donate to e Foundation | Murena handsets with /e/OS | Own a part of Murena! Learn more

Commit 07f169c3 authored by Mitch Williams's avatar Mitch Williams Committed by Jeff Kirsher
Browse files

i40e: add 20G speed for Tx bandwidth calculations



When calculating TX bandwidth for VFs, we need to know the link speed to
make sure we don't allocate more bandwidth than is available. Add 20G
link speed to the switch statement so we can support devices that link
at that speed.

Change-ID: I5409f6139d549e5832777db9c22ca0664e0c5f8b
Signed-off-by: default avatarMitch Williams <mitch.a.williams@intel.com>
Tested-by: default avatarAndrew Bowers <andrewx.bowers@intel.com>
Signed-off-by: default avatarJeff Kirsher <jeffrey.t.kirsher@intel.com>
parent 1d0a4ada
Loading
Loading
Loading
Loading
+3 −0
Original line number Diff line number Diff line
@@ -2306,6 +2306,9 @@ int i40e_ndo_set_vf_bw(struct net_device *netdev, int vf_id, int min_tx_rate,
	case I40E_LINK_SPEED_40GB:
		speed = 40000;
		break;
	case I40E_LINK_SPEED_20GB:
		speed = 20000;
		break;
	case I40E_LINK_SPEED_10GB:
		speed = 10000;
		break;