Loading arch/ia64/sn/kernel/io_init.c +10 −8 Original line number Diff line number Diff line Loading @@ -323,7 +323,7 @@ void sn_pci_controller_fixup(int segment, int busnum, struct pci_bus *bus) struct pci_controller *controller; struct pcibus_bussoft *prom_bussoft_ptr; struct hubdev_info *hubdev_info; void *provider_soft; void *provider_soft = NULL; struct sn_pcibus_provider *provider; status = sal_get_pcibus_info((u64) segment, (u64) busnum, Loading @@ -339,7 +339,7 @@ void sn_pci_controller_fixup(int segment, int busnum, struct pci_bus *bus) if (bus == NULL) { bus = pci_scan_bus(busnum, &pci_root_ops, controller); if (bus == NULL) return; /* error, or bus already scanned */ goto error_return; /* error, or bus already scanned */ bus->sysdata = NULL; } Loading @@ -352,28 +352,30 @@ void sn_pci_controller_fixup(int segment, int busnum, struct pci_bus *bus) */ if (prom_bussoft_ptr->bs_asic_type >= PCIIO_ASIC_MAX_TYPES) return; /* unsupported asic type */ goto error_return; /* unsupported asic type */ if (prom_bussoft_ptr->bs_asic_type == PCIIO_ASIC_TYPE_PPB) goto error_return; /* no further fixup necessary */ provider = sn_pci_provider[prom_bussoft_ptr->bs_asic_type]; if (provider == NULL) return; /* no provider registerd for this asic */ goto error_return; /* no provider registerd for this asic */ provider_soft = NULL; bus->sysdata = controller; if (provider->bus_fixup) provider_soft = (*provider->bus_fixup) (prom_bussoft_ptr, controller); if (provider_soft == NULL) return; /* fixup failed or not applicable */ if (provider_soft == NULL) { /* fixup failed or not applicable */ bus->sysdata = NULL; goto error_return; } /* * Generic bus fixup goes here. Don't reference prom_bussoft_ptr * after this point. */ bus->sysdata = controller; PCI_CONTROLLER(bus)->platform_data = provider_soft; nasid = NASID_GET(SN_PCIBUS_BUSSOFT(bus)->bs_base); cnode = nasid_to_cnodeid(nasid); Loading Loading
arch/ia64/sn/kernel/io_init.c +10 −8 Original line number Diff line number Diff line Loading @@ -323,7 +323,7 @@ void sn_pci_controller_fixup(int segment, int busnum, struct pci_bus *bus) struct pci_controller *controller; struct pcibus_bussoft *prom_bussoft_ptr; struct hubdev_info *hubdev_info; void *provider_soft; void *provider_soft = NULL; struct sn_pcibus_provider *provider; status = sal_get_pcibus_info((u64) segment, (u64) busnum, Loading @@ -339,7 +339,7 @@ void sn_pci_controller_fixup(int segment, int busnum, struct pci_bus *bus) if (bus == NULL) { bus = pci_scan_bus(busnum, &pci_root_ops, controller); if (bus == NULL) return; /* error, or bus already scanned */ goto error_return; /* error, or bus already scanned */ bus->sysdata = NULL; } Loading @@ -352,28 +352,30 @@ void sn_pci_controller_fixup(int segment, int busnum, struct pci_bus *bus) */ if (prom_bussoft_ptr->bs_asic_type >= PCIIO_ASIC_MAX_TYPES) return; /* unsupported asic type */ goto error_return; /* unsupported asic type */ if (prom_bussoft_ptr->bs_asic_type == PCIIO_ASIC_TYPE_PPB) goto error_return; /* no further fixup necessary */ provider = sn_pci_provider[prom_bussoft_ptr->bs_asic_type]; if (provider == NULL) return; /* no provider registerd for this asic */ goto error_return; /* no provider registerd for this asic */ provider_soft = NULL; bus->sysdata = controller; if (provider->bus_fixup) provider_soft = (*provider->bus_fixup) (prom_bussoft_ptr, controller); if (provider_soft == NULL) return; /* fixup failed or not applicable */ if (provider_soft == NULL) { /* fixup failed or not applicable */ bus->sysdata = NULL; goto error_return; } /* * Generic bus fixup goes here. Don't reference prom_bussoft_ptr * after this point. */ bus->sysdata = controller; PCI_CONTROLLER(bus)->platform_data = provider_soft; nasid = NASID_GET(SN_PCIBUS_BUSSOFT(bus)->bs_base); cnode = nasid_to_cnodeid(nasid); Loading